  • Page 1 SABRE™ SHIELD Rev 1.0...
  • Page 2 SABRE Shield Installation Guide Copyright Warranty Trademarks...
  • Page 3: Getting Started

    SABRE Shield Installation Guide Getting Started Congratulations on the purchase of your SABRE I Remote terminal and SABRE Shield. When you unpack the package, please check that the following items are present: SABRE I Remote terminal SABRE Shield Mounting Plate (including four allen screws with nuts and washers) Mounting Frame (including four bolts with nuts and washers) Two U-bolts with four washers and nuts Four screws (to secure terminal to base plate)
  • Page 4: Removing The Battery Door

    SABRE Shield Installation Guide Removing the Battery Door Follow these steps to remove the battery door: 1. Place your thumbs on the battery door as shown. 2. Push the battery door outwards in the direction shown. Removing the Battery Follow the step to remove the battery: 1.
  • Page 5: Installing Sim Card

    SABRE Shield Installation Guide Installing SIM Card Follow these steps to install the SIM card: 1. Insert the SIM card into the SIM slot with the gold-contacts facing out. 2. Push the SIM card in until it clicks and lock in place. SIM card Note: To remove the SIM card, push SIM card in.
  • Page 6 SABRE Shield Installation Guide Preparing the SABRE™ Shield Follow these steps to prepare the SABRE™ Shield: 1. Place the SABRE™ Shield on a flat surface. 2. Release the four cover screws and remove the cover. Cover Cover screws Screws Multi-function cable connector 3.
  • Page 7 SABRE Shield Installation Guide Installing SABRE™ I Remote Follow these steps to install the SABRE I Remote terminal inside the SABRE Shield: 1. Remove four screws securing base plate to the SABRE Shield. Phone (RJ11) cable connector Power plug Ethernet (RJ45) cable connector Screws Screws...
  • Page 8 SABRE Shield Installation Guide 5. Install four screws to secure the SABRE I Remote terminal to the base plate. Screws Screws Base plate 6. Using the velcro-tape, secure the SABRE I Remote terminal to the base plate as shown below. Velcro-tape...
  • Page 9 SABRE Shield Installation Guide 7. Install the base plate back to the SABRE Shield. 8. Install four screws to secure the base plate to the SABRE Shield. Screws Screws 9. Insert the power plug into the DC power input socket on the SABRE Remote terminal.
  • Page 10: Setting Up The Mounting Frame

    SABRE Shield Installation Guide Setting Up the Mounting Frame Follow these steps to setup the mounting frame: 1. Align the mounting frame. 2. Install four bolts with washers to secure the mounting frame together.
  • Page 11 SABRE Shield Installation Guide Installing Mounting Frame to Mounting Plate Follow these steps to install the mounting frame to the mounting plate: 1. Place mounting plate on the back of the mounting frame. Mounting frame Mounting plate 2. Place four nuts onto the four grooves located on the mounting plate. Grooves Grooves 3.
  • Page 12 SABRE Shield Installation Guide 10 Installing Mounting Plate to SABRE™ Shield Follow these steps to install the mounting plate to the SABRE Shield: 1. Place SABRE Shield on top of the mounting plate as shown below. 2. Drop the four allen screws to the four slot holes at each corner of the SABRE Shield.
  • Page 13 SABRE Shield Installation Guide 4. Install the SABRE Shield cover. 5. Tighten the the four cover screws to secure the SABRE Shield cover. Cover Cover screws Screws...
  • Page 14: Mounting The Sabre

    SABRE Shield Installation Guide Mounting the SABRE Shield Follow these steps to mount the SABRE Shield: 1. Locate a vertical pole or column to mount the SABRE Shield. 2. Mount the SABRE Shield to the vertical pole or column using two U-bolts, four nuts and washers.
  • Page 15: Positioning The Sabre

    SABRE Shield Installation Guide 4. Install the Multi-function cable header to the connector on the SABRE Shield. Multi-function cable header 12 Positioning the SABRE Shield Follow these steps to position the SABRE Shield: 1. Remove two lock bolts and nuts on either side of the mounting frame. 2.
  • Page 16 SABRE Shield Installation Guide Powering Up the SABRE I Remote Follow these steps to power up the SABRE I Remote terminal: 1. Insert the power adapter output plug into the DC power input socket on the Multi-function cable. Ethernet port Phone port DC power input...
  • Page 17 SABRE Shield Installation Guide 14 Connecting to your Computer via Ethernet Follow these steps to connect the SABRE I Remote terminal to your computer using Ethernet: 1. Insert one connector end of the Ethernet cable to the Multi-function cable’s Ethernet port. 2.
  • Page 18 2. Start your Internet browser. 3. Type http://192.168.1.35 in the Address field and press Enter. The Connect to 192.168.1.35 login screen appears. 4. Type in admin in the Username field and wideye in the Password field. Click OK.
  • Page 19 SABRE Shield Installation Guide 5. The SABRE I Web Console will appear on your screen. 6. Allow the terminal a few minutes to acquire the GPS co-ordinates. Once the GPS co-ordinates is acquired, the New GPS acquired message is displayed. Note: The GPS co-ordinates will not be displayed until you click Register Network to register to Inmarsat’s BGAN network.
  • Page 20: Registering With The Bgan Network

    SABRE Shield Installation Guide 16 Registering with the BGAN Network Establishing a connection with the BGAN network requires the careful orientation of the SABRE I Remote terminal towards the satellite, a process called antenna pointing. To perform antenna pointing, you will need a compass and the following information from the Web Console: Pointing Angle (Azimuth and Elevation) Signal stength indicator bar...
  • Page 21 SABRE Shield Installation Guide 5. Secure the mounting after obtaining maximum signal strength. Note: For any service to commence, minimum 45dBHz signal strength is required. 6. Click Register Network to register to the BGAN network. Once network registration is completed, the Registered to network. You are now able to make phone call or send SMS and data transfer message is displayed.
  • Page 22: Making A Phone Call

    SABRE Shield Installation Guide Making a Phone Call Follow these steps to make phone calls: 1. Connect a corded analog phone to the Multi-function cable’s Phone port. 2. Dial the other party’s number using the following format: 00 <country code> <phone number> followed by # key.
  • Page 23 SABRE Shield Installation Guide 18 Activate PDP Connection Follow these steps to activate the default profile: 1. Click Activate Default Profile. The PDP context will be activated. When connected, APN and IP Address details will be displayed. You can proceed to use the Internet features. Follow these steps to disconnect the data connection: 1.
  • Page 24 Part number: 74B00123030...