Site Preparation; Installation Site Requirements - Follett Maestro Plus MCD425A BS Installation Instructions Manual

Chewblet ice machine with ride technology installation instructions for ice storage bin
Table of Contents

Advertisement

2.

Site Preparation

Provide drainage, potable water supply and electrical power to within 6 feet (2m) of
ice machine in accordance with local and national codes. Outdoor installation is not
recommended and will void warranty.
2.1

Installation site requirements

Electrical
§ This appliance should be connected by a qualified person in accordance with application codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
MCD425(A/W)BS 115/60/1 (115 V ±10%) 15A breaker
(MCD requires a 15A dedicated circuit)
* Requires a 15A dedicated circuit.
Potable Water Supply
10 psi to 70 psi (69 kpa to 483kpa)
Condenser water supply for water-cooled systems
10 psi min.; 125 psi max. (69 kpa min.; 862 kpa max.)
20 F to 90 F (–7 C to 32 C)
0.5 gallons (1.9 liters) per minute
Drain
The drain line from the ice machine must have at least 1/4 in. per foot (6,4 mm/0,3 m) pitch
Bin  •  RIDE Technology 
115 V ±5%
230 V ±10%
220 V ±10%
115 V
NEMA
5-15
WARNING!
MCE425(A/W)BS (230/50/1 - 5.5A (full load)
(MCE425A/W requires a dedicated circuit, 1.50 mm
MCC425(A/W)BS (220/60/1 - 5.5A (full load)
(MCE425A/W requires a dedicated circuit)
45 F to 90 F (7 C to 32 C)
Maestro Plus
1/4"
1'
wire)
2
5