Page 3
Cool Heat MODE High Auto ON/OFF Fan only T-ON T-OFF AUTO SWING COOL SLEEP LOCK SPEED HEAT ON/OFF MODE SWING SLEEP TIMER...
Page 6
Cool Heat MODE SPEED Auto High ON/OFF Fan only Cool MODE SPEED Heat High Auto ON/OFF Fan only...
Page 7
Centrifugal blade Centrifugal blade Cooled air Hot discharged wind Compressor Evaporator Condenser Capillary Flowing direction of refrigerant...
Page 8
POWER BN(BK) ROOM TEMP. TUBE TEMP. OUTTUBE TEMP. WATER MOTOR SENSOR BU(WH) SENSOR SENSOR YEGN YEGN(GN) ROOM TUBE OUTTUBE WATER(WATER1) COMP. K201 MOTOR YEGN DISP2 COMP. DISP2 COMP R(M) DISP1 ELECTRIC BOX DISP1 HIGH-WP YEGN WATER LEVEL MOTOR SWITCH...
Buttons on Remote Controller ON/OFF button T-ON T-OFF MODE button AUTO SWING COOL SLEEP LOCK SPEED HEAT +/- botton MODE ON/OFF FAN button SWING SWING button SLEEP TIMER SLEEP button TIMER button Icon Display on Remote Controller Timer on Timer off Sending signal T-ON T-OFF For auto operation...
Page 13
When selecting auto mode, air conditioner will operate automatically according to ex-factory setting. Set temperature can't be adjusted and won't be displayed either. Press FAN button to adjust fan speed. (This function is not available in this air conditioner.) When selecting cool mode, air conditioner will operate under cool mode. Then press + or - button to adjust set temperature. Pr ess FAN button to adjust fan speed.
Replacement of Batteries in Remote Controller battery 1. Press the back side of remote controller on the spot marked with , and then push out the cover of battery box along the arrow direction. 2. Replace two No.7 (AAA 1.5V) dry batteries and make sure the positions of + and -- polar are correct.
Page 15
Tamb. cooling 26℃ drying 24℃ 23℃ fan or drying 20℃ Tamb. Starting cooling Tset+1℃ Original operating status Tset-1℃ Note Stop cooling 6min 3min 6min Stop Compressor set fan speed...
Page 23
Troubleshooting for F1,F2,F4 malfunction the wiring terminal between the temperature sensor and the controller loosened or poorly contacted? Insert the temperature sensor tightly Is malfunction eliminated Is there short circuit due to trip over of the parts? Make the parts upright Is malfunction eliminated Is the...
Page 24
Troubleshooting for E5 malfunction Is the supply voltage unstable Normal fluctuation is within 10 % of the rated Malfunction is with big fluctuation? voltage on the nameplate eliminated Is the supply voltage too low Malfunction is Malfunction is Adjust the supply voltage to maintain it within with overload? eliminated normal range...
Page 25
Start up the unit H8 is displayed Discharge water by referring Whether water tray is full to instruction manual Check whether wires for water-level Whether malfunction switch are connected tightly is eliminated? Adjust connection Whether malfunction Replace water-level is eliminated? Whether malfunction switch is eliminated?
Page 26
Troubleshooting for F0 malfunction Heat exchangers are Clean the heat exchangers and remove Malfunction is too dirty or the air inlet/outlet eliminated. blockage of air inlet/outlet. is blocked. Compressor doesn't work Malfunction is Make compressor run normally. normally. Strange noise or leakage occurs. eliminated.
Page 27
Troubleshooting for H3 malfunction Heat exchangers are Clean the heat exchangers and remove Malfunction is too dirty or the air inlet/outlet eliminated. blockage of air inlet/outlet. is blocked. Fan motor is not working Check motor and re-install the moto Malfunction is Abnormal fan speed;...
Page 28
Troubleshooting for E8 malfunction Operate the unit after ambient tempeature and Whether the environment Malfunction is humidity is decreased or move the unit to the eliminated. is formidable. place with low abient temprature and humidity. Heat exchangers are Clean the heat exchangers and remove Malfunction is too dirty or the air inlet/outlet...