Carefree of Colorado
E
MERGENCY
If the original power source fails or is unavailable, the Travel'r has emergency
override terminals (12V). The terminals can be used with a 10V-18V power
source, such as a cordless drill battery or car battery.
D
O NOT CONNECT THE
To use the emergency terminals:
D
O NOT USE THE EMERGENCY TERMINALS WITHOUT FOLLOWING THE DIRECTIONS BELOW
T
HE ELECTRONIC CIRCUIT CREATES A DYNAMIC BRAKE FOR THE MOTOR BY SHORTING
AND GROUNDING THE MOTOR LEADS
1.
Remove the switch from the mounting surface.
2.
Disconnect the connector from the back of the switch.
3.
Attach jumper leads to the emergency terminals located on the rear of the
RH motorized head.
4.
Connect the other ends of the jumper leads to a 12V source. If the awning
does not begin to move, reverse the leads.
5.
Maintain contact throughout the retraction process.
B
E CAREFUL WHEN RETRACTING THE AWNING AS THE AWNING MAY MOVE ABRUPTLY
4