Kensence S-Mix-Pro 80*80 Operation Manual

Professional modular matrix switcher

Advertisement

Quick Links

S-Mix-Pro 9*9/18*18/40*40/80*80

Professional Modular Matrix Switcher
Operation manual
Shenzhen Avctime Technology Co.,Ltd
Version:V1.01.01
2015-12

Advertisement

Table of Contents
loading

Summary of Contents for Kensence S-Mix-Pro 80*80

  • Page 1: S-Mix-Pro 9*9/18*18/40*40/80*80

    S-Mix-Pro 9*9/18*18/40*40/80*80 Professional Modular Matrix Switcher Operation manual Shenzhen Avctime Technology Co.,Ltd Version:V1.01.01 2015-12...
  • Page 2: Table Of Contents

    Contents S-Mix-Pro 9*9/18*18/40*40/80*80....................1 1.Introduction.............................4 2. Product Features..........................4 3. Connection and operation......................5 4. Standard configuration........................6 5.Specification...........................7 6.Description of operation and function..................9 6.1 Description of front panel....................9 6.2 Touch screen control instructions..................11 6.3 PC control software operation instructions..............16 6.4 Video switching operation....................18 6.5 Operation of control, resolution, name change etc.
  • Page 3 Safety Reminder To protect the device and operating personnel from electrostatic discharge, you need to check and ensure that the device is grounding good before the device is powered on. Please observe the following when you install, use, maintain this equipment. Make sure the device ground connection.
  • Page 4: Introduction

    1.Introduction S-Mix-Pro series is a kind of professional enhanced HD modular matrix. The plug-in design can realize the flexible configuration of various signal. Supports common video signal input, such as HDMI, DVI, VGA, YPBPR, DP, CVBS, 3G/HD/SD-SDI, IP streaming media, etc., supports powerful audio embedding and demultiplexing function. This series matrix integrated control signal (RS232/IP) transmission and control functions, support system state input/output signal intelligent monitoring, intelligent signal automatic backup, dual control backup, dual power backup.
  • Page 5: Connection And Operation

    3.Connection and operation Note: do not operate on the matrix within 2 minutes of the start of the matrix!!! 1.Connect signal source such as blu-ray player、game controller、A/V receiver、cables、 satellite receiver etc. to the HDMI input port of the matrix. 2.Connect the output port of the matrix to HD display or HD projector with HDMI input port.Notice:It’s better to use High-Speed HDMI Cable when the transmission distance is too long.
  • Page 6: Standard Configuration

    4.Standard configuration Please check the outer package before using this product. Please contact us if the product is faulted or not intact. We will sincerely serve you according to relevant provisions. Name Quantity Unit S-Mix-Pro Matrix Host Dryer 50g AC power adapter Certification Warranty card User manual...
  • Page 7: Specification

    5.Specification S-Mix-Pro 9x9 S-Mix-Pro 18x18 S-Mix-Pro 40x40 S-Mix-Pro 80x80 Model 9 ways enhanced 18 ways enhanced 40 ways enhanced 80 ways enhanced Description HD modular matrix HD modular matrix HD modular matrix HD modular matrix Input/Output 18/18 40/20 80/40 Input / output Support CVBS、...
  • Page 8 Operating 0ºC~40ºC temperature Storage −20ºC~60ºC Temperature...
  • Page 9: Description Of Operation And Function

    6.Description of operation and function 6.1 Description of front panel Figure 6.1.1 S-MIX-PRO99 front panel Figure 6.1.2 S-MIX-PRO-99 rear panel...
  • Page 10 Figure 6.1.3 S-MIX-PRO-1818 front panel Figure 6.1.4 S-MIX-PRO-1818 rear panel...
  • Page 11: Touch Screen Control Instructions

    6.2 Touch screen control instructions S-MIX-PRO series matrix can control the matrix through the front panel HD touch screen, which contains four operating interface,that is VIEW , SWITCH, SCENE, SETUP . 1.VIEW interface: as shown in Figure 6.2.1,this interface can show current input and output status of the matrix, the figure 6.2.1 says the current sixth input signal switching to output signal 02, 03, 04, 06, 07, 08, while the current input and output can be saved in the right side of the interface, it has 13 scenarios from 01 to 13 for users, select any number...
  • Page 12 selected more, as shown in Figure 6.2.2 it selected "06, 07, 08, 12"output signal, and then click "Apply ", and then click "Take" to complete the switch. As mentioned above, the "08" input signal can be switched to 08, 06,, 08, 12,, output signal. When operation, click "UnPickALL (choose all options)", you can select all the output ports, click "PickALL (cancel all options), click"...
  • Page 13 Figure 6.2.3 SCENE interface 4.SETUP interface:As shown in figure 6.2.4: this interface can set up buzzer on or off, video backup switch, IP address change, Chinese and English interface switching, etc. Figure 6.2.4 SETUP interface Buzzer switch: click the white box next to the "Buzzer" , pop-up digital keyboard, enter the on/off, click "ENTER"...
  • Page 14 Figure 6.2.4.1 Turn on / off the buzzer Video backup switch:the operation is similar with buzzer switch, click the white box next to the "Backup" , pop-up digital keyboard, enter the on/off, click "ENTER" and then click "Save" to save. Video backup function: backup function exists in the input signal 1 with 2, 3 and 4 , the input signal 2 and 4 is the backup signal.
  • Page 15 Figure 6.2.4.2 LAN port selection interface IP address change: click the white box on the right side of "IPaddr1" , pop-up digital keyboard, you can change the IP address, after the completion of the change, click "ENTER" and then click "Save" to save, as shown in figure 6.2.4.3 Figure 6.2.4.3: IP change...
  • Page 16: Pc Control Software Operation Instructions

    6.3 PC control software operation instructions MIX- control software is a green software, do not need to install, double-click the main program to use. Through RS232 serial line or cable to connect to matrix and computer, through the MIX control software to control the matrix. Note: please set the computer's IP and matrix's IP in the same segment.
  • Page 17 Figure 6.3.1 Network connection 2) serial connection: use direct serial lines to connect computer and matrix, double-click to open the control software, click "SETUP" button to determine COM ports, such as COM1, select "COM1" in serial device, click "serial connection", when the lower right corner of all the buttons shown in green, the connection is successful.
  • Page 18: Video Switching Operation

    3) change IP: when serial port or ethernet control connection is normal, enter the IP changed in the network address in configuration bar , click Save to change IP. 4 Buzzer on / off:when serial port or network port control connection is normal, click "open"...
  • Page 19: Operation Of Control, Resolution, Name Change Etc. Of Input / Output Cards

    6.5 Operation of control, resolution, name change etc. of input / output cards. 1) Input card:double click the input signal in "SWITCH " interface, pop-up interface in figure 6.5.1 , in "control" column in which we can control the camera and other equipment connected to the card(this function needs to ask suppliers for relevant information, command sent form see table 1).
  • Page 20: Scene Save Operation

    Figure 6.5.2 Output card central control, video control, name operation interface 6.6 Scene save operation Click "VIEW" button, pop up interface as shown in figure 6.6.1, click on the right side the scene 1 ~ 12 you want to preserve in this interface , press "SAVE" button to save the current scene.
  • Page 21: Scene Load

    6.7 Scene load Click on the "SCENE" button, pop-up interface as shown in figure 6.7.1,call the scene in the right side of the screen,and can view the selected scene of the input and output in the interface, and finally click "Load " button to call the selected scene. Figure 6.7.1 Scene load...
  • Page 22: External Serial Port Command Sending

    6.8 External serial port command sending External serial port command sending format is as follows (black character fixed, "parameters" in red characters means the string command to be send , "length" is the length of the string command, "packet length" is equal to "length" plus 12 then converted to hexadecimal) packet length...
  • Page 23: Communication Protocol And Control Instruction Code

    Communication protocol and control instruction code Communication protocol:(Baud rate 115200, data bits 8, stop bit 1, no parity bit ) control Type Functional description instruction aXb.take. Switch a channel input to b channel output aX1-b.take. Switch a channel input to 1-b channel output Operat aXb1,b2,b3.take.
  • Page 24: Version And Manufacture Information

    Contact Us Shenzhen Avctime Technology CO.,LTD Address :RM301-10, BuildingA,NO.196 Tangtou blvd , Shixin Community , Shiyan Town ,Baoan District , Shenzhen City,China ,518101 Tel:86-0755-29377262-818 Website:http://www.kensence.net/ Email:tiffany@kensence.com Skype: tiffany_1726 You can contact our dealers and distributors for ordering or technical supporting...

This manual is also suitable for:

S-mix-pro 40*40S-mix-pro 18*18S-mix-pro 9*9

Table of Contents