BANTE Bante210 Instruction Manual

BANTE Bante210 Instruction Manual

Benchtop ph meter

Advertisement

Bante210 Benchtop pH Meter
Instruction Manual
BANTE INSTRUMENTS LIMITED

Advertisement

Table of Contents
loading

Summary of Contents for BANTE Bante210

  • Page 1 Bante210 Benchtop pH Meter Instruction Manual BANTE INSTRUMENTS LIMITED...
  • Page 2 Introduction Thank you for selecting the Bante210 benchtop pH meter. This manual provides a step-by-step guide to help you operate the meter, please carefully read the following instructions before use. The following list describes the standard accessories of the meter. After the unpacking, please check all accessories are complete.
  • Page 3: Connecting The Electrode Holder

    ENTER Connecting the Electrode Holder Bante210 benchtop pH meter comes with an easy-to-use holder for mounting the pH electrode and temperature probe. If necessary, follow the steps below to install the electrode holder. The base of the electrode holder with an irregular round hole.
  • Page 4 Bante210 Benchtop pH Meter Insert the plastic rod into the irregular round hole and swivel the electrode arm 90 . Electrode holder is now ready to swing into desired position. ADJUSTMENT OF ELECTRODE ARM: After installation, if the electrode arm automatically rises or falls, you need to adjust the screws until arm locate at any position.
  • Page 5: Connecting The Temperature Probe

    DO NOT pull on the sensor cord. Always make sure that the connector is clean and dry. Connecting the Temperature Probe Bante210 benchtop pH meter comes with a temperature probe for measuring temperature of the sample. When probe is connected to meter, Automatic Temperature Compensation function will immediately start.
  • Page 6: Connecting The Power Adapter

    Insert the connector of power adapter into the power socket on the meter. The meter is now ready for use. Preparing the pH Buffer Solutions Bante210 benchtop pH meter is packaged with three pH buffer packets required for calibration. ●...
  • Page 7: Prior To Use

    If you do not press any key for 3 hours, the meter will turn off automatically.  To disable the auto-off function, please read the SETUP MENU section. Setup Menu Bante210 benchtop pH meter contains an integrated setup menu that allows you to customize each displayed option to meet measurement requirements. PARAMETER DESCRIPTION OPTIONS...
  • Page 8: Setting The Default Parameters

    Bante210 Benchtop pH Meter Setting the Default Parameters Press and hold the key for 3 seconds to enter setup menu, the meter shows default pH buffer option. Setup    Press key to select the option or value  Press ENTER key to confirm or MEAS key to return to measurement mode Press ...
  • Page 9: Exit The Setup Menu

    Bante210 Benchtop pH Meter Press  or  key to enable or disable the auto-hold function, press ENTER key to confirm. The meter shows “OFF/NO” indicating that the auto-off function is disabled. Setup    Press key to select the option or value ...
  • Page 10: Automatic Temperature Compensation

    Bante210 Benchtop pH Meter Temperature Compensation In order to get accurate measuring results, you need to enable the manual or automatic temperature compensation before measurement or calibration. AUTOMATIC TEMPERATURE COMPENSATION: Insert the connector of temperature probe into corresponding “ATC” socket, the display immediately shows “ATC” indicator. The meter is now switched to automatic temperature compensation mode.
  • Page 11: Single Point Calibration

    Bante210 Benchtop pH Meter pH Calibration Bante210 benchtop pH meter allows 1 to 3 points calibration. We recommend that you perform at least 2 points calibration for high accuracy measurement. The meter will automatically recognize and calibrate to following standard buffer values.
  • Page 12 Bante210 Benchtop pH Meter Rinse the pH electrode with distilled water. Dip the electrode into the pH4.01 or 10.01 (pH4.01 or 9.18) standard buffer solution. Stir the sensor gently. Press ENTER key to confirm. Wait for the measured value to stabilize, the display shows electrode slope and “END”. Second point calibration is completed.
  • Page 13: Temperature Calibration

    Bante210 Benchtop pH Meter Press ENTER key to confirm. Wait for the measured value to stabilize, the display shows electrode slope and “END”. The meter automatically returns to measurement mode. Calibration is completed.  ● During the calibration, if the meter shows “Err”, please check the pH electrode and calibration solutions are fresh and uncontaminated.
  • Page 14: Hold Function

    Hold Function Bante210 benchtop pH meter contains two data hold modes. When the Auto-Hold function is enabled, the meter will automatically sense a stable endpoint reading and freeze it, “HOLD” indicator appears on the display. If the Auto-Hold function is disabled, press key, the meter will immediately freeze currently displayed value.
  • Page 15: Sample Type

    Bante210 Benchtop pH Meter Optional pH Electrodes Bante210 benchtop pH meter is equipped with a general purpose pH electrode, if it can not fully meet your measurement requirements, please refer to the table below to select an applicable sensor. SAMPLE TYPE ●...
  • Page 16: Specifications

    Bante210 Benchtop pH Meter Specifications Model Bante210 Range -1.00~15.00pH Accuracy ± 0.01pH Calibration Points 1 to 3 points Calibration Solutions USA (pH4.01/7.00/10.01) or NIST (pH4.01/6.86/9.18) Range -1000~1000mV Accuracy ± 1mV Resolution Range 0~105° C, 32~221° F Accuracy ± 1° C...
  • Page 17 Hazardous Substance Statement Bante Instruments Limited is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium, lead, mercury and the like.

Table of Contents