BANTE POL-200 Instruction Manual

Semiautomatic polarimeter

Advertisement

Quick Links

POL-200 Semiautomatic Polarimeter
Instruction Manual
BANTE INSTRUMENTS LIMITED

Advertisement

Table of Contents
loading

Summary of Contents for BANTE POL-200

  • Page 1 POL-200 Semiautomatic Polarimeter Instruction Manual BANTE INSTRUMENTS LIMITED...
  • Page 2: Unpacking The Instrument

    DO NOT pull out the power plug from the power source if the instrument does not completely turned off, that may cause the zero-point offset. Display POL-200 semiautomatic polarimeter is equipped with the 5.6 inch touch screen that used to show measured values, function keys and help message. In the measurement and setting modes, the instrument will show different user interfaces.
  • Page 3: Setup Menu

    POL-200 Semiautomatic Polarimeter Setup Menu POL-200 semiautomatic polarimeter contains an integrated setup menu that allows you to customize each option to meet measurement requirements. Selectable parameters contain the following options. INDEX: PARAMETER OPTION DESCRIPTION ● Optical Rotation ● Specific Rotation Measurement Mode Select your desired measurement mode.
  • Page 4: Setting The Parameter

    POL-200 Semiautomatic Polarimeter SETTING THE PARAMETER: Click the Setup icon to enter the setup menu, select a parameter you want to set. Press  or  key to select an option or press the numeric keys to input the setting value.
  • Page 5 Measurement POL-200 semiautomatic polarimeter can be used for measuring the four parameters, including the optical rotation, specific rotation, concentration and International Sugar Scale. Click the Setup icon to enter the setup menu, then click the “Measurement Mode” icon to select desired measurement mode.
  • Page 6: Storing And Recalling Data From Memory

    POL-200 Semiautomatic Polarimeter Storing and Recalling Data from Memory POL-200 semiautomatic polarimeter allows up to 100 data sets to be stored and recalled. MEMORY INPUT: During the measurement, click the Save icon, the screen shows a dialog box and wait for entering the sample name.
  • Page 7: Memory Recall

    POL-200 Semiautomatic Polarimeter MEMORY RECALL: Click the Data icon during the measurement mode, the screen shows the stored measured values.  Press Page key, the screen will toggle to next page. Delete………. …….……Page If you need to delete stored data, press Delete key, all of the data will be deleted.
  • Page 8 POL-200 Semiautomatic Polarimeter Calibration POL-200 semiautomatic polarimeter allows 1 to 3 points calibration, but calibration is not required unless the measured value appeared serious deviation. Click the Setup icon during the measurement mode, the screen shows the setup menu. Click the Calibration icon, the instrument enters the calibration mode.
  • Page 9: Restore Factory Settings

    POL-200 Semiautomatic Polarimeter Place the standard tube into the sample chamber, press number keys to enter calibration value, press ENTER key to confirm. Press  or  key until visual field appear uniform brightness, press ENTER key to confirm. The instrument returns to zero-point automatically.
  • Page 10: Specifications

    POL-200 Semiautomatic Polarimeter Specifications Model POL-200 Measurement Modes Optical Rotation, Specific Rotation, Concentration, International Sugar Scale Measuring Range ± 90° , ± 130° Z Accuracy ± 0.02° , ± 0.05° Z Resolution 0.005° Wavelength 589nm Light Source LED, Interference filter...
  • Page 11 Hazardous Substance Statement Bante Instruments is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium, lead, mercury and the like.