X11DDW-L/NT User's Manual
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Fan Fail and UID LED
Connect an LED cable to pins 7 and 8 of the front control panel to use the Overheat/Fan
Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure. Refer
to the tables below for pin definitions.
OH/Fan Fail Indicator
Status
State
Definition
Off
Normal
On
Overheat
Flashing
Fan Fail
Power Button
PWR
Reset Button
Reset
1
Power Fail
2
UID LED
NIC2 Activity LED
NIC1 Activity LED
HDD LED
Power LED
X
NMI
Power Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
3.3V
6
PWR Supply Fail
1
2
Ground
Ground
3.3V
3
OH/Fan Fail LED
3.3V Stby
3.3V Stby
3.3V Stby
3.3V
X
Ground
19
20
44
OH/Fan Fail LED
Pin Definitions (JF1)
Pin# Definition
7
Blue LED
8
OH/Fan Fail LED
1. Power Fail LED