Technical Data - EINHELL RT-XM 305 Original Operating Instructions

Universal crosscut saw
Table of Contents

Advertisement

Anleitung_RT_XM_305_SPK7:_
GB
All persons who use and service the equipment have
to be acquainted with this manual and must be
informed about the machine's potential hazards. It is
also imperative to observe the accident prevention
regulations in force in your area. The same applies for
the general rules of health and safety at work.
The manufacturer will not be liable for any changes
made to the equipment nor for any damage resulting
from such changes. Even when the equipment is
used as prescribed it is still impossible to eliminate
certain residual risk factors. The following hazards
may arise in connection with the machine's
construction and design:
Contact with the saw blade in the uncovered saw
zone.
Reaching into the running saw blade (cut
injuries).
Kick-back of workpieces and parts of workpieces.
Saw blade fracturing.
Catapulting of faulty carbide tips from the saw
blade.
Damage to hearing if ear-muffs are not used as
necessary.
Harmful emissions of metal and wood dust when
used in closed rooms.
Cut injuries through contact with chips and
workpieces.
Eye injuries caused by small metal chips.

5. Technical data

AC motor:
240V ~ 50Hz
Power:
Operating mode:
Idle speed n
:
2,500 min
0
Carbide saw blade:
ø 250 x ø 30 x 2.2 mm
Number of teeth:
Swiveling range:
-52° / 0°/ +60°
Miter cut:
0° to 45° to the left
Saw width at 90°:
Wood:
305 x 75 mm
Metal:
105 x 75 mm
Saw width at 45°:
Wood:
210 x 75 mm
Metal:
70 x 75 mm
Saw width at 2 x 45° (double miter cut):
Wood:
210 x 40 mm
Metal:
70 x 40 mm
Weight:
approx. 17.5 kg
10
22.06.2010
15:46 Uhr
Sound and vibration
Sound and vibration values were measured in
accordance with EN 61029.
L
sound pressure level
pA
K
uncertainty
pA
L
sound power level
WA
K
uncertainty
WA
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Total vibration values (vector sum of three directions)
determined in accordance with EN 61029.
Vibration emission value a
= 1.068 m/s
h
K uncertainty = 1.5 m/s
2
Warning!
The specified vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equipment
is used and may exceed the specified value in
exceptional circumstances.
The specified vibration value can be used to compare
the equipment with other electric power tools.
The specified vibration value can be used for initial
assessment of a harmful effect.
Keep the noise emissions and vibrations to a
1800 W
minimum.
S1
Only use appliances which are in perfect working
-1
order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
48
Do not overload the appliance.
Have the appliance serviced whenever
necessary.
Switch the appliance off when it is not in use.
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain residual
risks cannot be rules out. The following hazards
may arise in connection with the equipment's
construction and layout:
1. Lung damage if no suitable protective dust mask
is used.
2. Damage to hearing if no suitable ear protection is
used.
3. Health damage caused by hand-arm vibrations if
Seite 10
93.7 dB(A)
3 dB
108.5 dB(A)
3 dB
2

Advertisement

Table of Contents