Technical Data; Before Starting The Equipment - EINHELL TC-TS 2225 U Original Operating Instructions

Bench-type circular saw
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25
Saw blade fracturing.
Catapulting of faulty carbide tips from the saw
blade.
Damage to hearing if essential ear-muffs are
not used.
Harmful emissions of wood dust when used
in closed rooms.

4. Technical data

AC motor ..................................220-240V ~ 50Hz
Power P ..................S1 1800 W · S6 25% 2200 W
Idling speed n
..................................... 4250 rpm
0
Carbide saw blade .......... Ø 254 x Ø 30 x 2.4 mm
Number of teeth ............................................... 48
Table size ...................................... 580 x 555 mm
Table width extension left/right ...... 580 x 150 mm
Table length extension, width ................. 555 mm
Support surface max. .................. 830 x 1055 mm
Cutting height max. ........................... 80 mm / 90°
........................................................ 55 mm / 45°
Height adjustment .................... infi nite 0 - 80 mm
Tilting saw blade .......................... infi nite 0° - 45°
Cross stop angle ....................... infi nite -45° - 45°
Extractor connection .............................Ø 36 mm
Weight ........................................ approx. 26.5 kg
Protection class: ........................................... II/
Thickness of the splitter .......................... 2.0 mm
Operating mode S6 25%: Continuous operation
with idling (cycle time 10 minutes). To ensure that
the motor does not become excessively hot, it
may only be operated for 25% of the cycle at the
specifi ed rating and must then be allowed to idle
for 75% of the cycle.
Danger!
Noise
The noise emission values were measured in ac-
cordance with EN 62841.
Operation
L
sound pressure level ..................... 93.2 dB(A)
pA
K
uncertainty ........................................ 3 dB(A)
pA
L
sound power level ..................... 106.2 dB(A)
WA
K
uncertainty ........................................ 3 dB(A)
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Anl_TC-TS_2225_U_SPK13.indb 27
GB
The stated noise emission values were measured
in accordance with a set of standardized criteria
and can be used to compare one power tool with
another.
The stated noise emission values can also be
used to make an initial assessment of exposure.
Warning:
The noise emission levels may vary from the level
specifi ed during actual use, depending on the
way in which the power tool is used, especially
the type of workpiece it is used for.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Limit the operating time!
All stages of the operating cycle must be conside-
red (for example, times in which the electric tools
are switched off and times in which the tool is
switched on but operates without load).
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
- 27 -
31.01.2024 10:33:30

Advertisement

Table of Contents
loading

This manual is also suitable for:

4340515

Table of Contents