9.7 Drop Impact Strength (without packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop the scanner 18 times in total (3 times at each 6 face), from a height of 150 cm
onto a concrete floor as shown below.
9.8 Drop Impact Strength (in individual packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges,
and 6 faces, from a height of 150 cm onto a concrete floor.
9.9 Electrostatic Discharge Immunity
Air discharge
Measurement environment
Discharge resistance
Charging capacitor
SPECIFICATIONS MANUAL
Figure 8: Drop Test
±8 kV max. (No malfunction)
±15 kV max. (No destruction)
An electrostatic testing device compliant with IEC 61000-4-2
330 Ω
150 pF
OPN-2102i
1st
150cm
18