Minimum clearance
Fitting
822.0213 MA / EN
Installation instructions for solar charge regulator LRM 1218
Ensure a minimum clearance to the surrounding fixtures and fittings:
"
Maintain a gap of at least 5 cm on all sides (except mounted side).
F
Whilst in operation, the ambient temperature must not exceed +45 C,
F
measured 2.5 cm away from the sides of the device.
On a stable and even surface, attach the solar charge regulator to the
"
drillholes with two screws (Fig. 1, Pos. 5).
Fig. 3
Attachment points for LRM 1218 solar charge regulator (dimensions in mm)
5
Electrical connection
ATTENTION!
Y
The output voltage of the charge regulator is also suitable for direct supply
without battery. The solar charge regulator must be set accordingly for
this however.
The electrical connection of the solar charge regulator is ready for the follo-
wing applications:
Connections to leisure area battery and starter battery
F
Connection to an EBL ... electroblock with connected DT ... / LT ...
F
control and display panel
Connection to an EBL ... electroblock with 3-pin MNL connection and
F
adapter for starter battery
Connection to 3-pin MNL connector and adapter for starter battery
F
and SDTBUS connector (bus systems)
Date: 22.07.2015
130.7
119
ø4 (2x)
3
5