Delta 36-729 Instruction Manual page 18

10" cabinet saw
Hide thumbs Also See for 36-729:
Table of Contents

Advertisement

MITER GAGE OPERATION AND
A
ADJUSTMENT
The miter gage is equipped with adjustable index stops at
C
90 degrees and 45 degrees right and left. Adjustment to the
index stops can be made by tightening or loosening the
three adjusting screws (B) Fig. 40, with allen wrench
supplied.
To rotate the miter gage, loosen lock knob (A) Fig. 40, flip the
stop link (D) down and out of the way, and move the body
B
of the miter gage (C), to the desired angle.
The miter gage body (C) can stop at 90 degrees and 45
degrees both right and left by flipping the stop link down
B
B
and out of the way and moving the miter gage body (C) past
D
the 90 and 45 degrees mark and flipping the stop link (D)
back up so that the stop link (D) will be able to contact the
Fig. 40
adjusting screws (B) at the desired 90 or 45 degree angle. To
rotate the miter gage body past these points, the stop link
(D) Fig. 40, must be down and out of the way.
Your miter gage is equipped with a plate which fits into the
T-Slot groove in the table. This allows the miter gage to be
pulled off the front edge of the table without falling. This
allows for a longer cut off capacity in front of the blade.
18

Hide quick links:

Advertisement

Table of Contents
loading