Cessna 177 SERIES Service Manual page 123

1968 thru 1978
Hide thumbs Also See for 177 SERIES:
Table of Contents

Advertisement

jumper wires from a 12-volt power source to
4.
Mount an inclinometer on one flap and adjust
operate the flap motor.
The leads may be
to 30°'2°-0
° .
reversed to change motor direction or a 3-
position switch (spring-loaded to center OFF
NOTE
position) may be used.
Use caution when ap-
proaching travel extremes as there is no pro-
An inclinometer for measuring control sur-
vision for freewheeling in the transmission.
face travel is available from the Cessna
Service Parts Center.
Refer to figure 6-4.
I
1.
Complete steps 2 thru 5 of subparagraph
"a."
5.
Using the external power supply and jumpers,
2.
(Refer to figure 7-2.)
Using the external
run the flaps FULL UP AND FORWARD (0
°
) and ad-
power source and jumpers, run the actuator guide
just the UP-LIMIT switch (17) to operate and shut-off
assembly (7) to .12±, 05" between guide assembly
motor at this position. DO NOT ALLOW GUIDE
(7) and transmission (4) as illustrated in VIEW A-A.
ASSEMBLY TO REACH THE END OF THE SCREW
Adjust the DOWN-LIMIT switch (18) to operate and
ASSEMBLY.
shut-off motor at this position. DO NOT ALLOW
6.
Connect the electrical quick-disconnect (15)
GUIDE ASSEMBLY TO SEAT AGAINST TRANSMIS-
at the flap motor.
SION.
7.
Complete steps 14 thru 21 of subparagraph
*
3.
Complete steps 6 thru 10 of subparagraph "a."
"a."
Change 3
7-9/(7-10 blank)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents