Updating Firmware; Transmitter Controls - Shure AD1 Manual

Bodypack transmitter
Hide thumbs Also See for AD1:
Table of Contents

Advertisement

AD1
AD1 Bodypack Transmitter
Bodypack rechargeable lithium-ion battery
Y-Cable for bodypack transmitters
LEMO Y-cable for bodypack transmitters
Instrument cable
AD1 Transmitter Overview
① RF Antenna
For RF signal transmission.
② Display
View menu screens and settings. Press any control button to activate the
backlight.
③ Infrared (IR) Port
Align with the receiver IR port during an IR Sync for automated transmitter
tuning and setup.
④ Control Buttons
Use to navigate through parameter menus and to change settings.
⑤ Battery Compartment
Requires two AA batteries or Shure SB900A rechargeable battery.
⑥ AA Battery Adapter
Use to secure AA batteries. Remove when using a Shure SB900A battery.
⑦ SMA Connector
Connection point for RF antenna.
⑧ Power Switch
Powers the unit on or off.
⑨ Power LED
Green = unit is powered on
Red = low battery, Mute Mode enabled, input overload, or battery error
(see Troubleshooting)
Amber = power switch mode: locked with switch in off position

Updating Firmware

Firmware is embedded software in each component that controls functional-
ity. Periodically, new versions of firmware are developed to incorporate addi-
tional features and enhancements. To take advantage of design improve-
ments, new versions of the firmware can be uploaded and installed using
the Shure Update Utility. The Shure Update Utility is available for download
from http://www.shure.com/.
Firmware Versioning
When performing an update, download firmware to the receiver first, and
then update transmitters to the same firmware version to ensure consistent
operation.

Transmitter Controls

Use the controls to navigate through parameter menus and change values.
2/12
SB900A
AXT652
AXT652LEMO3
WA302
⑩ Input Jack
Connects to a 4-Pin Mini Connector (TA4F) microphone or instrument cable.
Note: A LEMO connector model variation of this transmitter is available.
The firmware numbering for Shure devices uses the following format: MA-
JOR.MINOR.PATCH (e.g., 1.2.14). At a minimum, all devices on the network
(including transmitters), must have the same MAJOR and MINOR firmware
version numbers (e.g., 1.2.x).
Updating the Transmitter
1. To upload the firmware to the transmitter, go to Device Configuration>Tx
2. Place the transmitter on its side and align the IR ports.
3. Press ENTER on the receiver to begin the download to the transmitter.
Replacement belt clip
Instrument cable with right angle 1/4"
connector
Mute Switch for Bodypack
Mute Switch for 2 Bodypacks
1
2
3
4
5
6
Firmware Update on the receiver.
IR ports must be aligned for the entire download, which can take 50
seconds or longer.
Shure Incorporated
44A12547
WA304
WA661
WA662
7
8
9
10
2017/08/03