Optical Switch Operating Parameters - Cisco GS7000 Installation And Configuration Manual

Optical
Table of Contents

Advertisement

Chapter 3
Setup and Operation

Optical Switch Operating Parameters

This section is a reference for the operating parameters of the optical switch. The
optical switch is configured through the Status Monitor/Local Control Module in
the node. Refer to the Model GS7000 Hub/Node Status Monitor/Local Control Module
Installation and Configuration Guide, part number OL-29937-01, for complete
instructions on configuring the optical switch.
Switch Operation
The following table describes the optical switch function.
Primary Input
Path A Optical Power >
ThresholdA (default)
Path A Optical Power <
ThresholdA (default)
Path B Optical Power >
ThresholdB [1]
Path A Optical Power <
ThresholdA (default)
Path B Optical Power >
ThresholdB (User Setting)
Path B Optical Power <
ThresholdB (User Setting)
Path B Optical Power >
ThresholdB (User Setting)
Path B Optical Power <
ThresholdB (User Setting)
[1] Hysteresis Amplitude (default 1.0 dB) is the value above which the input
optical power must rise for the switch to begin sequence to return to the primary
switch position. Hysteresis Amplitude is a user configurable parameter.
Configurable Parameters
The following table defines the configurable parameters for the optical switch.
Parameter
Function
Mode
Automatic or manual
mode
ThresholdB
Switching threshold,
input optical power at
input B
74
Secondary Input
Path B Optical Power >
ThresholdB [1]
Path B Optical Power >
ThresholdB [1]
Path B Optical Power <
ThresholdB [1]
Path B Optical Power <
ThresholdB [1]
Path A Optical Power >
ThresholdA [1]
Path A Optical Power >
ThresholdA [1]
Path A Optical Power <
ThresholdA [1]
Path A Optical Power <
ThresholdA [1]
Default
Value
Auto(0)
5.0
Alarms
None
Loss of Input Light
at Path A
Loss of Input Light
at Path B
Both Dark
None
Loss of Input Light
at Path B
Loss of Input Light
at Path A
Both Dark
Values
Min
Auto(0)
Manual(1)
-10.0
Optical Switch
Switch to Path A
Switch to Path B
Optical Power
Switch to Path A
Switch to Path A
Optical Power
Switch to Path B
Switch to Path A
Optical Power
Switch to Path B
Switch to Path B
Optical Power
Max
Step
Unit
14.0
0.1
dBm
OL-29936-01

Advertisement

Table of Contents
loading

Table of Contents