Eye Pattern - Aiwa CSD-A310 HA Service Manual

Compact disc stereo cassette recorder
Hide thumbs Also See for CSD-A310 HA:
Table of Contents

Advertisement

ADJUSTMENT <TUNER / DECK / CD>
< RADIO SECTION >
1. AM Frequency Range Adjustment
• Test Point: TP5 (LCH), TP6 (RCH)
• Adjustment location: L006, TC003
• Method:
L006 ....................................................................... 517kHz
TC003 ................................................................... 1750kHz
2. AM Tracking Adjustment
• Test Point: TP5 (LCH), TP6 (RCH)
• Adjustment location: L003, TC004
• Method:
L003 ....................................................................... 600kHz
TC004 ................................................................... 1400kHz
3. AM IF Adjustment
• Test Point: TP5 (LCH), TP6 (RCH)
• Adjustment location: L007
• Method:
L007 ....................................................................... 455kHz
4. FM Frequency Range Adjustment
• Test Point: TP5 (LCH), TP6 (RCH)
• Adjustment location: L005, TC001
• Method:
L005 ........................................................................ 87MHz
TC001 .................................................................... 109MHz
5. FM Tracking Adjustment
• Test Point: TP5 (LCH), TP6 (RCH)
• Adjustment location: L004, TC002
• Method:
L004 ........................................................................ 88MHz
TC002 .................................................................... 108MHz
6. FM IF Adjustment
• Test Point: TP5 (LCH), TP6 (RCH)
• Adjustment location: L008, L009
• Method:
L008, L009 ........................................................... 10.7MHz
< TAPE RECORDER SECTION >
1. Bias Adjustment
• Test tape: TTA-630
• Test Point: TP2
• Adjustment location: L801
• Method:
L801 .............................................................. 85kHz±2kHz
2. Azimuth Adjustment
Condition: • Test tape: TTA-320
• Test point: PHONE JACK
• Adjustment location: Azimuth adjustment
Method:
Play back the test tape and adjust the screw so that the
output is maximum.
screw
< CD SECTION >
1. Focus Bias Adjustment
Make the focus bias adjustment when replacing and repairing
the optical block.
TP3 (RF)
TP4 (VREF)
1) Connect an oscilloscope to the test point TP3 (RF) and TP4
(VREF).
2) Turn on the power switch.
3) Insert test disc TCD-782 (YEDS-18) and play back the second
composition.
4) Adjust SFR430 so that RF signal of the test point TP3 (RF) is
MAX and CLEAREST.

EYE PATTERN

must be CLEAR and MAX
– 24 –
Oscilloscope
(DC range)
+
-
MAX
0V
VOLT / DIV: 200mV
TIME / DIV: 0.5µs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csd-a319 lhCsd-a310Csd-a310 hcCsd-a310 ez' csd-a310 g

Table of Contents