Bw (3) Bandwidths; Pbt (4) Pass Band Tuning; Band (7); Split (8) - Ten-Tec Argonaut VI 539 User Manual

Hide thumbs Also See for Argonaut VI 539:
Table of Contents

Advertisement

Argonaut VI

BW (3) Bandwidths

Adjusting the BW control will allow you to
select the DSP filtering of your choice. This
will increase the selectivity of receive and
helps remove close in unwanted signals.
The range of the DSP filters is 100hz to
2500hz in 25hz increments. When the
optional 6kHz filter is installed, this permits
4k, 5k, and 6k DSP bandwidth selections.
When dealing with crowded band conditions
and close in adjoining signals one will find
this control
very useful as you begin to
narrow the filter to eliminate close in
unwanted
signals.
automatically select the correct roofing filter
ahead of the DSP filtering provided a specific
roofing filter is installed.

PBT (4) Pass Band Tuning

Verify that the PBT control is at 12 0'clock to
begin listening in all modes.
The PBT control will allow you to move the
passband back and forth across the desired
signal. It is beneficial in dropping QRM out
of one side or the other of the passband or it
can simply be used to improve the quality and
intelligibility of the signal.
experiment for digital communications is to
work the PBT control along with the BW
bandwidth control for the greatest selectivity
and interfering signal rejection.
539 / Argonaut VI Users manual
Part #74479
Printed in USA
2
1
3
Figure 2-1 539 Front Panel- (with indexes)
This
control
will
An excellent
Release 0.10 – November 13, 2012
9
7 8
5
4

Band (7)

Be sure TMB switch is in Middle position. To
change bands or toggle through the Ham
bands press the BAN button and the next
Ham band will be recalled. BAN will only
toggle through the Ham bands in one
direction. When the band is changed, the A
Frequency, the B Frequency and the Mode
are recalled from the last time the band was
used. Since the Mode is recalled, the Tuning
Rate, and the AGC will also be recalled from
the last time that Mode was used.

Split (8)

To operate SPLIT mode be sure TMB switch
is in the Top position. Press SPL (PRE)
button. The word SPLIT will appear between
VFO A and VFO B. VFO B will show the
transmitted frequency in smaller font. To exit
SPLIT mode, press the SPL (PRE) button one
more time turning off the word SPLIT.

AGC (9)

Be sure TMB switch is in the Top position.
Press AGC (NR) button will toggle the AGC
between fast, medium, and slow. The letter
F, M, or S will appear below the last digit on
VFO A

A/B (10)

Be sure TMB switch is in the Top position.
When you press and hold the A/B (MOD)
button you will now be able to set B VFO to
equal VFO A. A quick press of the A/B
(MOD) button will reverse both A and B
VFO.
9
10
6

Hide quick links:

Advertisement

Table of Contents
loading