Performance Data Sheet - GE Pro Elite 268-716-150-1248 Operation Manual

Pro elite analyzer professional series water treatment system
Table of Contents

Advertisement

Performance Data Sheet

Model
Rated Service Flow (gpm)
Pressure Drop at Rated
Service Flow Rate (psi)
Rated Capacity
(grains @ lb of salt)
Rated Efficiency
(grains/lb Salt @ lb of salt)
Maximum FLow Rate
During Regeneration (gpm)
10% Cross Linked Ion
Exchange Resin (cu ft)
Tank Size
Backwash - GPM
Rapid Rinse/Purge - GPM
Operating Pressure: 20-125 psi or 1.4-8.8 kg/cm
Acceptable Salt Type: Sodium Chloride - Pellet salt
All Systems above tested at 35 psi ±5 psi, pH of 7.5 ±0.5, Capacity Testing Flow Rate = 50% of the rated service flow
rate for the various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific
performance claims as verified and substantiated by test data. The rated salt efficiencies above were also
determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced above. An
efficiency rated water softener is a demand initiated regeneration (DIR) softener which also complies with
specific performance specifications intended to minimize the amount of regenerant brine and water used
in its operation. Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350
grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total
hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating. The rated
efficiency of the water softener, the salt dosage at that efficiency, the capacity at that salt dosage and
that of the efficiency is only valid at the stated salt dosage. Efficiency is measured by a laboratory test
described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve.
Operational efficiency is the actual efficiency achieved after the system has been installed. It is typically
less than the efficiency due to individual application factors including water hardness, water usage, and
other contaminants that reduce the water softener's capacity. These systems are not intended to be used
for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system. Refer to the system Installation and Service Manals for set-up and programming
instructions.
Contact your local dealer for parts and service. See your owner's manual for warranty information.
Iowa Requirement:
Seller: _________________________________________
Buyer: _________________________________________
12/4/13
Pro Elite Analyzer Water Softener System Performance Data Sheet
Pro Elite
268-716-100-1044
Analyzer
8.0
5.5
13,309 @ 3.3 lbs
26,327 @ 9.0 lbs
31,682 @ 15.0 lbs
4,033 grains/lb @ 3.3 lbs
5.5
1.0
10" x 44"
2.7
5.5
, Operating Temperature: 34-110°F or 1.1-43.3°C
2
Date: ______________________
Date: ______________________
PENTAIR Residential Filtration, LLC
5730 North Glen Park Road
Milwaukee, Wisconsin 53209
PHONE: (262) 238-4400
Pro Elite
268-716-150-1248
Analyzer
13.0
9.5
20,023 @4.95 lbs
39,609 @ 13.5 lbs
47,665 @ 22.5 lbs
4,045 grains/lb @ 4.95 lbs.
5.5
1.5
12" x 48"
3.9
5.5
3
Pro Elite
268-716-200-1248
Analyzer
15.0
14.4
28, 548 @ 6.6 lbs
56,472 @ 18.0 lbs
67,958 @ 30.0 lbs
4,325 grains/lb @ 6.6 lbs
5.5
2.0
12" x 48"
3.9
5.5
Tested and Certified by
the WQA to NSF/ANSI
Standard 44 & 372 for
softener performance &
lead free compliance and
CSA B483.1.