Programming Overview

The Analyzer control includes multiple program levels
that allow the Water Treatment Professional to customize
the system for many water conditions. Additionally,
historical data can be viewed allowing quick and easy
troubleshooting. In most cases, Level I programming is all
that is required to set up the water conditioning system
for proper operation. A brief description of each program
level is listed below.
Level l: Used to program control for normal
applications..
Level ll: (P-Values) Allows the installer to customize
programming for non-standard applications.
Level lll: (C-Values) Allows the installer to adjust the
length of select cycles for non-standard applications.
Level IV: History (H-Values) Allows access to historical
information for troubleshooting the system.
Note: If a button is not pushed for thirty seconds, the
control returns to normal operation mode.

Analyzer Control Operation

Power Loss Memory Retention
The Analyzer control features battery-free Time of Day
and Day of Week retention during loss of power. A super
capacitor is designed to hold the information in memory
for 8 to 24 hours depending on the installation. If the
super capacitor is exhausted, the Analyzer control will
display four dashes (- - :- -) immediately upon power up.
The Time of Day and Day of Week must be reset.
All other programmed parameters are stored in the static
memory and are retained during power outages.

Level I Programming

The Analyzer control can be quickly programmed by
following the sequential procedure on the following
page. Level I program parameters are those that can be
accessed by pressing the UP or DOWN buttons.
• Valve Type: Select 268 for traditional refilling the salt
tank last. Select 268r to have a normally dry salt
tank that is filled when the regeneration cycle starts.
• Resin Volume Setting: Set to match the volume
(cubic feet) of resin in the mineral tank.
• Time of Day: Includes PM indicator. Can be set to
display as a 24-hour clock. See Level ll Programming.
• Day of Week: Set to actual day of the week.
• Time of Regeneration: Fully adjustable. Default is
2:00 AM.
• Days Override: Range 0.5 to 99 days. Leave at 0 to
disable.
• Salt Dosage: Set at pounds of salt per cubic foot of
resin in the conditioner tank.
Note: When the control is set up for a twelve-hour clock
a PM indicator will illuminate when the displayed time is
in the PM hours. There is no AM indicator.