Wiring Diagrams; Wiring Diagrams - Single Phase - Daikin FCAG35AVEB Technical Data Manual

Table of Contents

Advertisement

7

Wiring diagrams

7 - 1 Wiring Diagrams - Single Phase

FCAG-A
7
1
2
3
Outdoor
(note 3)
H05VV-U4G2.5
(Note 7)
In case of simultaneous
operation system (note 5)
1
1
1
2
2
2
3
3
3
X2M
X2M
X2M
Remote control
X24A
X23A
X50A
X6A
X33A
X70A
Position of connectors in control box
A1P
Main PCB
C105
Capacitor
F1U
Fuse (T, 3.15A, 250V)
DS1
Dip switch on PCB
H1P
Flashing lamp (service monitor green)
K2R
Magnetic relay (drain pump)
M1P
Motor (drain pump)
M1F
Motor (indoor fan)
M1S-M4S
Motor (swing blade)
R1T
Thermistor (air)
R2T, R3T
Thermistor (coil)
V1R
Diode bridge
X1M
Terminal block (remote control)
X2M
Terminal block (power supply)
Z1C, Z2C
Ferrite core
Z1F
PS
Power supply circuit
RC
Signal receiver circuit
TC
Signal transmission circuit
NE
Noiseless earth
A3P, A4P
Sensor kit PCB
Infrared remote control (receiver/display unit)
A5P
Receiver PCB
A6P
Display PCB
BS1
Push button (on/off)
H1P
Pilot lamp (on: red)
1.
: terminal block,
2. In case of simultaneous operation indoor unit system, see the indoor unit wiring only.
3. For details, see wiring diagram attached to the outdoor unit.
4. In case of using central remote control, connect it to the unit in accordance with the attached installation manual.
5. In case of simultaneous operation system, connected quantity of the indoor units varies according to the connected outdoor unit.
6. In case of main/sub changeover, see installation manual attached to the remote control.
7. Shown only in case of protection piping, use H07RN-F in case of no protection.
8. X35A, X39A, X70A are connected when optional accessories are being used (auto clean panel), see wiring diagram of this accessory.
9. Connect power of adapter for wiring to terminal block (X2M) of indoor unit directly.
10. Colors: BLK: Black, RED: Red, BLU: Blue, WHT: White, YLW: Yellow, GRN: Green, BRN: Brown, PPL: Purple, PNK: Pink, ORG: Orange.
12
• Indoor Unit • FCAG-A
R2T
R1T
GR
S1L
N
Indoor
Z2C
N=1
NE
X15A X18A
X16A
K2R
X2M
X27A
F1U
1
BLK
Z1F
2
WH
T
3
RED
X33A
TC
RC
PE
A7P
Terminal for
X1A
F1U
operation display
X2A
X1
Compressor
KHuR
KC
F2U
X2
operation
Y
R
X3
KFR
C Y2
Fan operation
X4
Adapter for wiring (optional) (note 9)
A1
P
X2M
X39A
X35A
Indoor unit
Sensor kit
: connector,
• Split - Sky Air • FCAG-A
Sensor kit (optional)
A4P
A3P
R3T
A2P
X17A
X83A
X81A
V1R
C105
PS
H1P
X35A
X20A
X70A
Z1C
N=1
MSW
MSW
MS
M4S
M3S
M1F
H2P
Pilot lamp (timer: green)
H3P
H4P
Pilot lamp (defrost: orange)
H5P
Pilot lamp (element cleaning: red)
H6P
Pilot lamp (timer: green)
DS1
Dip switch (main/sub)
DS2
Dip switch (wireless address set)
A7P
Adapter PCB
F1U
Fuse (5A, 250V)
F2U
Fuse (5A, 250V)
KHuR
Magnetic relay
KCR
Magnetic relay
KFR
Magnetic relay
X1A
Connector (power supply for option PCB)
X2A
Connector (sensor kit)
X24A
Connector (infrared remote control)
X33A
Connector (adapter for wiring)
X35A
Connector (auto clean panel)
X39A
Connector (auto clean panel)
X70A
Connector (auto clean panel)
X81A
Sensor kit
R1T
Thermistor (air)
A2P
Sensor PCB
X1M
PNK
T2
Input from outside
WH
T1
F2
T YLW
Central remote
F1
ORG
control (note 4)
BLU
P2
P1
BL
K
A1P
X30A
X39A
A5P
OFF
ON
X2A
EMG.
X1A
Norm.
STB.
X24A
DS1
X36A
DS1
X25A
OFF
ON
DS2
OFF
ON
Receiver/display unit (optional)
MS
MSW
MSW
M1P
M2S
M1S
Adapter for wiring
Connectors for optional parts
Wired remote control
Humidity sensor
Wired remote
control
(note 6)
P
R1T
N
A6P
BS1
X1A
H1P
H2P
H3P
H4P
H5P
H6P
3 109572