Control Diagram - Swegon CASA R3 Smart Installation, Commissioning And Maintenance Instructions

Table of Contents

Advertisement

7.5 Control diagram

1
2
4
3
1: Group electrical distribution box | 2: Electrical equipment cubicle | 3: Exhaust air | 4: Outdoor air | 5: Power supply: 230 V, 10 A
with plug-in connection | 6: The damming height of the water trap, 100 mm | 7: Supply demarcation of the ventilation unit | 8:
Extraction from cooker hood, bypasses the heat exchanger | 9: General ventilation | 10: Supply air | 11: Cooker hood |
12: Modular cables with RJ9-connectors | 13: Control panel
SYMBOL
DESIGNATION
T1
TEMPERATURE SENSOR
T3
TEMPERATURE SENSOR
T4
TEMPERATURE SENSOR
T5
TEMPERATURE SENSOR
TC01
THERMOSTAT
TZ03
OVERHEATING PROTECTION
HSx.1
CONTACT
F1
FILTER
F2
FILTER
HR
HEAT EXCHANGER
SF1
FAN
EF1
FAN
RH
REHEATING
DESCRIPTION OF THE FUNCTIONS
CONTROL FUNCTIONS:
The ventilation unit can be operated from a separate Smart control panel or a Swegon CASA cooker hood.
When the ventilation unit is controlled from the cooker hood in the Home/Away/Boost modes and for local extraction, the time can be set to 30, 60
or 120 minutes.
The supply air temperature is controlled from the Smart control panel. When necessary, the reheating function can also be switched off from the
control panel.
– Overheating protection for the reheating air heater: The air heater is equipped with a TC01 automatic thermostat with manual reset (preset limit
value: 90 °C) as protection against overheating.
– The fans have automatic overtemperature protective devices.
REMEDIAL MEASURES TO TAKE IF THE SAFETY EQUIPMENT TRIPS:
– If an overheating protection with manual reset trips, locate and correct the fault; then press the reset button inside the ventilation unit.
– The automatic overheating protections of the fans will reset themselves when the temperature has dropped below the setting value.
26
www.swegonhomesolutions.com
5
6
EXPLANATION
Temperature sensor, outdoor air
Temperature sensor, extract air
Temperature sensor, air heater
Temperature sensor, exhaust air
Overheating protection, air heater
Overheating protection, air heater
Contact, timer for the cooker hood damper
Supply air filter
Extract air filter
Rotary heat exchanger
Supply air fan
Extract air fan
Supply air heating, accessory
RH
7
Swegon reserves the right to alter specifications.
R3.051016
12
13
10
9
11
8

Advertisement

Table of Contents
loading

Table of Contents