Cables and Pinouts
10/100BASE-TX Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP)
cable for RJ-45 connections: 100-ohm Category 3 or better cable
for 10 Mbps connections, or 100-ohm Category 5 or better cable
for 100 Mbps connections. Also be sure that the length of any
twisted-pair connection does not exceed 100 meters (328 feet).
The RJ-45 port on the access point is wired with MDI pinouts.
This means that you must use crossover cables for connections
to PCs or servers, and straight-through cable for connections to
switches or hubs. However, when connecting to devices that
support automatic MDI/MDI-X pinout configuration, you can use
either straight-through or crossover cable.
B-2
10/100BASE-TX MDI Port Pinouts
Pin
MDI Signal Name
1
Transmit Data plus (TD+)
2
Transmit Data minus (TD-)
3
Receive Data plus (RD+)
4
GND (Positive Vport)
5
GND (Positive Vport)
6
Receive Data minus (RD-)
7
-48V feeding power (Negative- Vport)
8
-48V feeding power (Negative- Vport)
Note: The "+" and "-" signs represent the polarity of the wires that make
up each wire pair.