4.2MAX. Refrigerant pipe length and height difference:
*Do your best to reduce the pipe length. Long pipe may cause capacity of the indoor unit incline.
Outdoor unit precharged
AUW-18H4SU
AUW-24H4SZ
AUW-36H6SA
AUW-48H6SP
AUW-60H6SP
Outdoor unit precharged
AUW-18H4SU1
AUW-24H4SZ1
AUD-36H6SA1
AUD-36H6S1A1
AUW-48H6SE1
AUW-60H6SP1
UNITARY AIR CONDITIONER TECHNICAL& SERVICE MANUAL V6.0
A
A
0m~5m
1200g
0g
1650g
0g
2300g
0g
3100g
0g
3300g
0g
0m~5m
1200g
0g
1650g
0g
2300g
0g
2300g
0g
2400g
0g
3100g
0g
Total refrigerant pipe length
Exceed 5m
Xg = 15g / m × (Total pipe length(m) -5)
Xg =35g / m × (Total pipe length(m) -5)
Total refrigerant pipe length
Exceed 5m
Xg = 15g / m × (Total pipe length(m) -5)
Xg =35g / m × (Total pipe length(m) -5)