Hisense GBF18H-S User Manual page 24

Table of Contents

Advertisement

2
.
S
P
E
C
I
F
I
C
A
T
I
O
N
2
.
S
P
E
C
I
F
I
C
A
T
I
O
N
Indoor model:
Outdoor model:
Dimensions WxHxD
Indoor Unit
(mm)
Net Weight (Kg)
Indoor Unit
Packing Dimensions
Indoor Unit
WxHxD (mm)
Gross Weight (Kg)
Indoor Unit
Loading Capacity
(20/40'/40' HC)
Test conditions:
Cooling : Indoor: DB27℃/ WB19℃ Outdoor: DB35℃/ WB24℃
Heating: Indoor: DB20℃/ WB15℃
Remarks:
1.The above design and specifications are subject to change without prior notice for product
improvement.
2.The values given in the table for noise level reflect the levels in anechoic chamber.
This heat pump air conditioner has been designed for the following temperatures.
Operate the heat pump air conditioner within this range.
Storage condition: Temperature -20~65℃
Humidity
ON/OFF UNITARY AIR CONDITIONER TECHNICAL& SERVICE MANUAL V6.0
S
S
AUV-18HR4SU
A
AUV-18HR4SA
AUW-18H4SU
990x680x230
27
1100x820x350
33
55/116/122
Outdoor: DB7℃/ WB 6℃
30%~80%
AUV-24HR4S
AUV-36HR6S
ZA
AB
AUV-24HR4S
AUV-36HR4S
A
B
AUW-24H4SZ
AUW-36H6SA
990x680x230
1285x680x230
37
28
1100x820x350
1400x820x350
34
44
45/99/105
33/67/74
AUV-48HR6SP
AUV-60HR6S
C
PC
AUV-60HR4S
AUV-48HR4SC
C
AUW-48H6SP
AUW-60H6SP
1580x680x230
1580x680x230
46
46
1690x820x350
1690x820x350
54
54
22/47/50
22/47/50
22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents