Installation
NETGEAR ProSAFE Dual Band Wireless AC

Access Point

WAC740

Package Contents

Unpack the box and verify the contents:
WAC740 ProSAFE Dual Band Wireless AC Access Point
Category 5e Ethernet cable
Ceiling mount kit
2nd Draft WAC740 QSG

Set Up the Access Point

Before mounting the access point in a high location, first set up and test the
access point to verify WiFi network connectivity.
You can deploy the WAC740 access point only in a WiFi
IMPORTANT:
network that is managed by a ProSAFE wireless controller.
¾ To cable the access point:
1. Connect an Ethernet cable from LAN port 1 on the access point to a
LAN port on a PoE+ switch, that is, an 802.3at-compatible switch.
2. Connect an Ethernet cable from the PoE+ switch to an Ethernet port on
the computer.
3. Check the LEDs to verify that the access point is set up correctly.
LED
Description
•Off. Power is off.
•Solid green. Power is on.
•Alternating green and amber. The access point receives insufficient PoE
Power LED
power.
•Solid amber, then blinking amber. A self-test is running or firmware is
being loaded. During startup, the Power LED first light solid amber, then
goes off, and then blinks amber before turning solid green after about
one minute. If after two minutes the Power LED remains solid amber or
continues to blink amber, it indicates a system fault.
•Off. No link with the network is detected.
•Solid green. A link with the network is detected.
•Blinking green. Network traffic is detected.
Activity LED
LED
Description
•Off. A 10 Mbps Ethernet link is detected or no Ethernet link is detected.
•Solid green. A 2.5 Gbps or 1 Gbps Mbps Ethernet link is detected.
If both LAN LED 1 and LAN LED 2 light solid green, the LAN ports are
members of a link aggregation group (LAG).
LAN LED 1
•Solid amber. A 100 Mbps Ethernet link is detected.
•Off. A 10 Mbps Ethernet link is detected or no Ethernet link is detected.
•Solid green. A 1 Gbps Ethernet link is detected.
If both LAN LED 1 and LAN LED 2 light solid green, the LAN ports are
members of a link aggregation group (LAG).
LAN LED 2
•Solid amber. A 100 Mbps Ethernet link is detected.
•Off. The 2.4 GHz WiFi radio is off.
•Solid green. The 2.4 GHz WiFi radio is on.
•Blinking green. WiFi activity is detected on the 2.4 GHz WiFi radio.
2.4G WLAN LED
•Off. The 5 GHz WiFi radio is off.
•Solid green. The 5 GHz WiFi radio is on.
•Blinking green. WiFi activity is detected on the 5 GHz WiFi radio.
5G WLAN LED
The access point uses a DHCP client that is enabled by default. If your network
includes a DHCP server, the access point obtains an IP address from the DHCP
server. If your network does not include a DHCP server, the access point sets
its IP address to a static IP address of 192.168.0.160.
If your network includes a DHCP server, note the following:
Make sure that option 43 is enabled on the DHCP server.
Make sure that the DHCP server specifies the IP address of the wireless
controller.
We recommend that you reserve an IP address for the access point on the
DHCP server.
If your network does not include a DHCP server, configure a computer with a
static IP address of 192.168.0.210 and a subnet mask of 255.255.255.0 so
you can connect to the access point at IP address 192.168.0.160.

Advertisement

loading

Summary of Contents for NETGEAR prosafe WAC740

  • Page 1: Set Up The Access Point

    ProSAFE wireless controller. •Off. A 10 Mbps Ethernet link is detected or no Ethernet link is detected. NETGEAR ProSAFE Dual Band Wireless AC ¾ To cable the access point: •Solid green. A 1 Gbps Ethernet link is detected.
  • Page 2: Deploy The Access Point

    ¾ To let the wireless controller discover the access point: Problem Cause Possible Solution Thank you for purchasing this NETGEAR product. You can visit No LEDs are lit The access •Make sure that the access point is securely connected to a PoE+ switch.
  • Page 3: Federal Communication Commission Interference Statement

    Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 4: Industry Canada Statement

    uncontrolled environment. This equipment should be installed and operated with minimum distance 37cm between the radiator & your body. Industry Canada statement: This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 5: Déclaration D'exposition Aux Radiations

    haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. Radiation Exposure Statement: This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment.