 DIP switch setting
• Remote controller address setting (SW100)
When operating a number of indoor units by using a wired remote controller, DIP switch setting
for assigning unit number to each indoor unit is required.
DIP switches are normally set to make the unit number 00.
Remote
controller
address
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Indoor unit
Remote controller
• Switch 1: Setting change prohibited (SW101)
• Switch 2: Setting change prohibited (SW101)
• Switch 3: Fan delay setting (SW101)
When the indoor unit is stopped while operating in conjunction with auxiliary heater, the indoor
unit fan operation will continue for 1 minute.
Switch 3
ON
OFF
DIP switch number
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
00
01
Fan delay
Enabled
Disabled
- 58 -
3
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
02
Remote controller address
Factory
setting
Factory setting