6. ELECTRICAL WIRING

]
WARNING
• Electrical work must be performed in accordance with this
Manual by a person certified under the national or regional
regulations. Be sure to use a dedicated circuit for the unit.
An insufficient power supply circuit or improperly
performed electrical work can cause serious accidents
such as electric shock or fire.
• Before starting work, check that power is not being
supplied to the indoor unit and outdoor unit.
• Use the included connection cables and power cables
or ones specified by the manufacturer. Improper
connections, insufficient insulation, or exceeding the
allowable current can cause electric shock or fire.
• For wiring, use the prescribed type of cables, connect
them securely, making sure that there are no external
forces of the cables applied to the terminal connections.
Improperly connected or secured cables can cause
serious accidents such as overheating the terminals,
electric shock, or fire.
• Do not modify the power cables, use extension cables,
or use any branches in the wiring. Improper connections,
insufficient insulation, or exceeding the allowable current
can cause electric shock or fire.
• Match the terminal board numbers and connection cable
colors with those of the outdoor unit. Erroneous wiring
may cause burning of the electric parts.
• Securely connect the connection cables to the terminal
board. In addition, secure the cables with wiring holders.
Improper connections, either in the wiring or at the ends
of the wiring, can cause a malfunction, electric shock, or
fire.
• Always fasten the outside covering of the connection
cable with the cable clamp. (If the insulator is chafed,
electric leakage may occur.)
• Securely install the electrical box cover on the unit.
An improperly installed electrical box cover can cause
serious accidents such as electric shock or fire through
exposure to dust or water.
• Install sleeves into any holes made in the walls for wiring.
• Install a ground leakage breaker. In addition, install the
• Install a ground leakage breaker.
• Always connect the ground cable.
• Install the remote control cables so as not to be direct
Connect the piping
• Perform wiring work in accordance with standards so that
• Connect the connection cable firmly to the terminal
• Ground the unit.
Do not connect the ground cable to a gas pipe, water
• Do not connect power supply cable to the transmission or
• Never bundle the power supply cable and transmission
• When handling PCB, static electricity charged in the body
Otherwise, a short circuit could result.
ground leakage breaker so that the entire AC main power
supply is cut off at the same time. Otherwise, electric
shock or fire could result.
If a ground leakage breaker is not installed, it may cause
electric shock or fire.
Improper grounding work can cause electric shocks.
touched with your hand.
the air conditioner can be operated safely and positively.
board. Imperfect installation may cause a fire.
CAUTION
pipe, lightning rod, or a telephone ground cable.
Improper grounding may cause electric shock.
remote control terminals, as this will damage the product.
cable together. Bundling these cables together will cause
miss operation.
may cause malfunction of the PCB. Follow the cautions
below:
• E stablish a ground for the indoor and outdoor units and
peripheral devices.
• Cut power (breaker) off.
• Touch metal part of the indoor and outdoor units for
more than 10 seconds to discharge static electricity
charged in the body.
• Do not touch terminals of parts and patterns
implemented on PCB.