FITTINGS
Illustration model TFT260/TMT260
Main chamber
with 1 Boston
1
valve
1 drain plug
Protected
transom
with motor
plate
Stiffening bars
Main chamber
(left and right)
with 1 Boston
valve
1
) TFT260/TMT260: 2 main chambers; TFT310: 3 air chambers
All models are supplied with carry bag and manometer / pressure gauge.
E
N
G
ASSEMBLY INSTRUCTIONS / INFLATION
L
I
Do not use sharp tools !
S
H
When inflating for the first time, inflate indoors at room temperature – the PVC will be soft and assembly will be easier. If
the item was stored below 0° C, leave it at 20° C for 12 hours before unfolding. Inflate it with an inflator from Sevylor or
any inflator designed for inflatable boats, rafts, and other low pressure inflatables. These types of inflators have a hose
and adaptors to fit the valves on this product.
Using an air compressor will damage your product and automatically void all warranties.
Choose a smooth and clean surface on which to unfold your boat.
1. First attach the stiffening bars to the transom: put one end of the stiffening bar through the hole on the rear wooden
board and hook the other end into the eyelet on the transom. NOTICE: The hook of the stiffening bars have to show
inwards.
2. Then familiarize yourself with the valves. Your boat is equipped with one type of valve:
Boston valve(s) – please see opposite figure : Unscrew the valve cap (1). Screw the
valve insert (2) onto its base (3) and check that the valve cap stays accessible. Insert the
pump hose end piece and inflate it until you will reach the required pressure (see point
3). After inflation fit all the valve(s) cap tightly (clockwise). NOTICE: A slight air-leak
before screwing the valve(s) cap is normal. Only the valve(s) cap can ensure final AIR
TIGHTNESS.
3. Inflate the boat in the order of inflation as shown on the capacity plate printed on the boat
(see also figure # 1 – numbering of the valves).
4. Max. air pressure : The correct pressure for this item is : 0,1 bar (= 100 mBar / 1.45 PSI). Do not exceed it.
Please check the pressure with the supplied pressure gauge (please refer to the "Instructions for the manometer")
Overpressure : deflate until you reach the recommended pressure. Pressure drop: inflate again slightly.
1
1
Wodden slats
1
Swivel oarlock
Wooden benches
Swivel oarlock
Zipper to get access to
the PVC inside bladder
CAUTION !
CAUTION !
4
Figure 1
Gear bag
3 handles
Grab line
Directional strakes
on the underside
(1) Valve cap
(
2) Valve
insert
3) Valve
(
base