THE HERAKLES DISHWASHER
Technical Training
Designation
Cycling pumps
Micro-motor
+
Alternate spraying disk
assembly
Filtering assembly
2
+
3
4
Function
Send the pressurized water into the two
spraying winches, the saucepan nozzle
and the ceiling small shower.
The pump is suspended and attached to
a silent block to eliminate the noise.
The sealed links between the pump, the
flap valve or dummy flap valve and the
heating tunnel also are flexible to
attenuate vibration noises. They are as
short as possible to limit dead volumes
and the heat dispersion.
The spiral shell is used to reduce this
volume, better canalize the water and
thus limit noises and risks of draining
(synchronous pumps). Because the air is
directly directed to the arms and venting
the pumps is thus not necessary.
The electronics measures the variations
in the current consumed by the pump, in
order to precisely adjust the quantity of
water taken during fillings according to
the needs of the moment.
Motorized disk: Direct the water from
cycling pump to lower and intermediate
winches and to the saucepan nozzle and
the ceiling small shower, using a disk
drilled with several holes.
Ensure complete water recycling with 4
filtering levels to trap all the dirt, even the
tiniest.
- main filter in stainless steel (1)
- plastic waste filter in 2 parts that cannot
be dismantled (2 + 3)
- micro-filter in nylon or stainless steel (4)
The tub water is filtered throughout the
cycle and the entire bath flows through
the filters several times per minute.
1
On some LCD programming, the "Filt"
message appears on the display after 20
cycles. It is then necessary to clean all
the filters.
LA3P-HERAKLES-001UK-0306
COMPONENTS
Features
Turbine with curved blades, so with
mandatory direction of rotation.
Motor: asynchronous
Main winding: 94Ω
Auxiliary winding: 126Ω
Power: 100W
Thermal protection: internal
Capacitor: 2.5 µF
Motorized disk: (on certain models)
A disk drilled with several holes of
different diameters is driven by a
synchronous micro-motor (piloted by the
power board). This system is used for
having alternate water supply to arms,
nozzle and small shower.
A contact located in the flap valve
enables the electronics to check the disk
position (5 closings/revolution) and a
ratchet prevents it from rotating in the
wrong direction.
Micro-motor ohmic value: 6.5 kΩ
Positioning contact verifiable with
ohmmeter, 0Ω between 5 and 6 of J5.
Located under the lower basket, they are
easily accessible and removable by the
consumer, for cleaning (eventually check
and clean the filter for big waste after
each washing).
Suction filtering to reduce the water
consumption with respect to a pulsed
filter.
- 29 -