THE HERAKLES DISHWASHER
Technical Training
Safety devices and "degraded mode" of the filling (continued)
Level L1 reached but after 35'' approximately: Low tap flow rate (< 1.5 l/min. approximately)
Filling is then performed in "degraded mode":
- the solenoid valve is supplied for a few seconds still after detection of level L1
- pause of 10" approximately and then check of the level
► level L1 is still present: the chronometric and static topping up is then set to 1' approximately
and the intake of water continues with the dynamic filling while monitoring the current
► level L1 is no longer present: leak or draining stick fallen
the current cycle is stopped and it is necessary to press "start" button to restart it

6.9. - The detection of dirt during the cycle

SV
Power
board
Float
FBS
Spray arm
Cycling
Filters
pump
Heating
tunnel
Current
analysis
LA3P-HERAKLES-001UK-0306
During the cycle, the electronics measures the pump
current. In the case of significant dirt, this current varies
abnormally (due to the presence of emulsion) an
additional rinse is then performed.
FUNCTION