Fagor Brandt HERAKLES LA3P 001UK-0306 Manual page 28

Table of Contents

Advertisement

COMPONENTS
Designation
Technical zone
Models with drying
by condenser
Models with
fan-assisted drying
Hydraulic unit
and level management
Float
FBS.
Softener assembly
Sel
Resins
Regeneration solenoid valve (RSV)
- 28 -
Function
Ensures the water distribution for the
washing and the regeneration.
The one that equips the models with fan-
assisted drying also ensures
condensation of the steam contained in
the tub during the drying.
The first filling phase is performed without
power supply to the cycling pump.
A float, located in the cycling unit,
actuates the contact of the flexible blade
switch (FBS) attached to the unit outside.
It gives "high level" information to the
printed circuit board.
Next, depending on the time taken to
reach this "high level", the board feeds
the solenoid valve in a chronometric way.
The last filling phase is performed by
cycling and monitoring the current
consumed by the pump. The solenoid
valve is cut off when this current is
stabilized.
Assembly consisting of a salt tank and a
resin tank linked by a conduit in which a
regeneration solenoid valve (RSV)
isolating the two tanks.
Is used for both retaining the limestone in
the resins and cleaning the resins with
salt water.
Is used for the regeneration by allowing
the brine passage from salt tank through
resins. The brine is pushed, by gravity, by
the reserve of hard water of the technical
zone.
CU3P-CDC-003-02/05
LA3P-HERAKLES-001UK-0306
THE HERAKLES DISHWASHER
Technical Training
Features
Distribution of water for fillings with soft
water (network to technical zone, and
then technical zone to resins and then
resins to technical zone and lastly
technical zone to cycling unit).
Reserve of hard water of the network for
the regeneration (technical zone to salt
tank).
The dishwasher filling is performed by the
cycling unit.
Because, a hose links the bottom of the
technical zone to the hydraulic unit.
Capacities:
- 1.4 Kg of regenerating salt
- 0.60 litre of resin
Electrical indicator of lack of salt: a
magnetized float actuates a flexible blade
contact (FBS) that is used to inform the
power board. This board will initiate the
power supply to an indicator light located
on the access board.
Filling:
Only use special dishwasher salt
(purified). The softener is compatible with
the table salt.
Supply voltage: 230V~
Ohmic value: approximately 4 kΩ
Supply time: 3 minutes