TPA-MHL2-8R – Quick Start Guide
Page 1
TPA-MHL2-8R

Quick Start Guide

Rev: B2
November 20, 2013
Revision B2

Advertisement

Table of Contents
loading

Summary of Contents for Quantum Data TPA-MHL2-8R

  • Page 1: Quick Start Guide

    TPA-MHL2-8R – Quick Start Guide Page 1 TPA-MHL2-8R Quick Start Guide Rev: B2 November 20, 2013 Revision B2...
  • Page 2: Table Of Contents

    1 Overview of MHL Scope of this Quick Start Guide 2 Quantum Data MHL Solutions TPA-MHL2-8R – Front Panel What is in the TPA-MHL2-8R shipping box Power Considerations 3 MHL Applications for Testing MHL Source Devices Protocol Analysis of MHL Sources MHL 2.0 Source Compliance Testing...
  • Page 3: Overview Of Mhl

    Quantum Data 980 HDMI Protocol Analyzer module. HDCP compliance testing requires the Quantum Data 882EA. TPA-MHL2-8R – Front Panel The front of the TPA-MHL2-8R is shown below. There are several LEDs and a couple of access pins. These are described in the table below: November 20, 2013...
  • Page 4 When lit, it indicates that there is a connection to the MHL port on this section. MHL SOURCE DUT The rear of the TPA-MHL2-8R is shown below. There are three application sections with associated connectors. The connections for each are described in the table below the diagram. TPA-MHL2-8R Section...
  • Page 5 TPA-MHL2-8R – Quick Start Guide Page 5 TPA-MHL2-8R Section Connector Label Connection TO PROTOCOL Connect HDMI cable to the Rx port on 980 MHL Protocol ANALYZER Analyzer. MHL -> HDMI MHL HDMI OUT This is an HDMI output. The device it gets connected to depends on the source test application.
  • Page 6: What Is In The Tpa-Mhl2-8R Shipping Box

    RG590A BNC cable 30-00125 (2) MHL Cables 30-00189 HDMI Cable 30-00146 Power Considerations The TPA-MHL2-8R is powered through a 12VDC source jack. The TPA-MHL2-8R is supplied with a12V DC power supply and charger and line cord. November 20, 2013 Revision B2...
  • Page 7: Mhl Applications For Testing Mhl Source Devices

    Protocol Analysis of MHL Sources You can conduct protocol analysis of MHL source devices using the TPA-MHL-8R and the Quantum Data 980 Protocol Analyzer. Protocol analysis enables you to view the timing, video type, control data and all metadata (e.g.
  • Page 8 Page 8 Use the procedures and diagrams below to make the connections to the TPA-MHL2-8R for running protocol analysis of an MHL source device. The first diagram shows a depiction of the test setup with the Rev. C 980 Protocol Analyzer module.
  • Page 9: Mhl 2.0 Source Compliance Testing

    TPA-MHL2-8R – Quick Start Guide Page 9 Connect an HDMI cable from the TO PROTOCOL ANALYZER RX connector of the TPA-MHL2-8R to the Rx port on the 980 HDMI Protocol Analyzer module. Refer to the 980 User Guide for details on how to capture, store and analyze data from the MHL source.
  • Page 10 The second diagram shows a depiction of the test setup with the Rev. D 980 Protocol Analyzer module. Apply power to the TPA-MHL2-8R using the power adapter provided. Make the connections as shown in the diagram below. For this application you will be using the section on the TPA-MHL2-8R labeled VIDEO ANALYSIS –...
  • Page 11: Hdcp Compliance Testing For Source Devices

    Quantum Data 882E product web page at: www.quantumdata.com/products/882E.asp. Use the procedure below to make the connections to the TPA-MHL2-8R for running the HDCP compliance tests on an MHL source device. Note that you will have to refer to the 882EA User Guide to run the HDCP compliance test.
  • Page 12: C-Bus Protocol Monitoring Of Mhl 2.0 Source And Sink Devices

    EDID exchange and HDCP authentication transactions in real time. For more details on the analysis features and functions of the 980, please refer to the Quantum Data products web page at: www.quantumdata.com/products/980.asp. Refer to the diagram below for a depiction of the test setup. Note that there are two 980 HDMI Protocol Analyzer configurations;...
  • Page 13 TPA-MHL2-8R – Quick Start Guide Page 13 November 20, 2013 Revision B2...
  • Page 14 Connect an MHL cable from the MHL source device under test to the MHL IN FROM SOURCE connector on the TPA-MHL2-8R. Connect a second MHL cable from the MHL OUT TO SINK connector on the TPA-MHL2-8R to the MHL sink device.
  • Page 15: Mhl Applications For Testing Mhl Sink/Dongle Devices

    MHL Sink Functional Testing You can run a functional test on an MHL sink using the TPA-MHL2-8R and an HDMI source device. However there are a couple important notes to be aware of about the limitations of functional testing at 1080p60 format resolution.
  • Page 16 If you wish to test 1080p60 you will need to put the TPA into the Packed Pixel mode using either the 980 with the HDMI Video Generator module or the 882. Refer to the Quantum Data website for the 980 User Guides or 882E User Guides in order to determine the commands necessary to put the TPA-MHL2-8R into the Packed Pixel mode.
  • Page 17: Mhl Sink/Dongle Compliance Testing

    You can run MHL compliance testing on MHL sink devices in accordance with Section 4 of the MHL Compliance Test Specification using the TPA-MHL2-8R, 882EA and the 980 HDMI Protocol and Compliance Controller. Note: You will have to purchase the MHL Sink/Dongle Compliance Test option as part of the 980 HDMI Protocol Analyzer to run this test series.
  • Page 18: November

    Connect an MHL cable from the MHL sink device under test to the MHL OUT TO DUT connector on the TPA-MHL2-8R. Connect an HDMI cable from the HDMI IN connector of the TPA-MHL2-8R to the appropriate port on the Encryption Status Tester (EST) and then to the 882EA HDMI OUT connector.