ABB LLT100 Operating Instructions Manual page 49

Laser level transmitter oi-llt100-en rev. d
Hide thumbs Also See for LLT100:
Table of Contents

Advertisement

Table 4
Errors
#
Error message
0
Level Sensor Failure
1
Temperature Sensor Failure
2
Illegal Memory Access
3
Safety Function Flow Failure
4
Level Sensor Out of Limits
5
Temperature Sensor Out of Limits
6
Self-Test Failure. Reset device
10
Level Sensor. Out of Range
16
Sensor board failure
17
Sensor Board Memory Failure
18
Sensor Board NV Write Error
19
Device Reset Required
20
Sensor Communication Failure
23
Electronics NV Failure
25
Electronics NV Syncing Information
30
HMI Validation Test Failure Reset device
31
Sensor Window Obstructed/Dirty
32
Electronics Insuff Input Voltage
33
Amb. Temp Out of Range
36
Data Simulation Warning
37
Alarm Simulation Warning
38
Current Output in Fixed Mode
39
Primary Current Uncertain
40
Electronics ROM Failure
41
Electronics RAM Failure
42
Target lost Error
43
Primary Current Saturated
44
Current Output Failure
45
Process Media Warning
46
Process Media Alarm
47
Invalid algorithm parameter
Action
Contact ABB service for replacement.
Contact ABB service for replacement.
Reset device. Contact ABB if condition persists.
Reset device. Contact ABB if condition persists.
Check for level sensor failure.
Check for temperature sensor failure.
Contact ABB if condition persists.
Check process.
Contact ABB service for replacement.
Reset device. Contact ABB if condition persists.
Reset device. Contact ABB if condition persists.
Cycle power for changes to take effect.
Reset device. Contact ABB if condition persists.
Contact ABB service.
Contact ABB service.
Replace LCD if condition persists.
Clean window. Contact ABB if condition persists.
Insufficient voltage to operate device.
Readings may be invalid due to improper ambient temperature. Correct ambient temperature.
One or more process values are in SIM mode.
One or more alarms are in simulation mode.
Process should be in manual control mode.
Contact ABB support if condition persists.
Contact ABB support if condition persists.
Contact ABB support if condition persists.
Check Process conditions.
Contact ABB support if condition persists.
Contact ABB support if condition persists.
Monitor Process Conditions.
Monitor Process Conditions.
Adjust configured Parameters.
OI-LLT100-EN Rev. D | User Guide 45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents