Vibration Measurements; Hydraulic Pressures - Wacker Neuson RD 12A Operator's Manual

Hide thumbs Also See for RD 12A:
Table of Contents

Advertisement

Technical Data
8.6

Vibration Measurements

8.7

Hydraulic Pressures

System
Operating Pressure
Drive**
55–69
Steering*
—while turning
Vibration
—single drum
55–76
* Values for hard-packed surface shown. Values may differ depending on surface.
** Charge pressure: 11.4 – 12.8 bar (165 –185 psi).
The operator of this machine should expect to be exposed to vibration
levels listed below when using the machine in performance of its
normally intended function:
Maximum hand/arm vibration levels are:
2
1.4 m/s
(4.6 ft/s
These are the representative values of the weighted root mean
square (rms) acceleration to which the hands and arms are sub-
jected. These weighted rms values are measured according to
ISO 5349-1.
Whole body vibration levels do not exceed:
2
0.22 m/s
(0.7 ft/s
These are the representative values of the weighted root mean
square (rms) acceleration to which the whole body is subjected.
These weighted rms values are measured according to ISO
2631-1.
The results are compliant to the limit and action vibration values (hand/
arm and whole body) as specified in European directive 2002/44/EC.
bar
psi
800–1000
0–41
0–725
800–1100
2
)
2
)
Relief Pressure
bar
psi
200
2900
45–51
650–725
200
2900
78
RD 12A
wc_td000411gb.fm