4.19 TTY setting commands
set tty flow
Function
Set the flow control.
set tty ttylist flow { xon | rs | none }
Format
Parameters
tty ttylist
flow { xon | rs | none }
• Do not use xon when bidirectionally transferring 8-bit code (binary, kanji etc.).
Note
Usage example Set flow control using RTS / CTS signal line for serial port 1.
Specify the tty number corresponding to the serial port in the 1 to 48 range.
The range of ports that you can specify varies depending on the model.
Specify a list of serial ports separated by hyphens "-" and commas "," to set
multiple ports in a single command.
Set the flow control.
This parameter is set to "none" by default.
xon
Control uses xon and xoff codes.
rs
Control the flow using RTS/CTS signals
none
Flow control is not used in both the transmitting and receiving directions.
set tty 1 flow rs