Samson 4708 Mounting And Operating Instructions page 18

Supply pressure regulator
Table of Contents

Advertisement

Pneumatic connections
Mounting the intermediate plate
1. Remove the fastening screws and lift the
supply pressure regulator (4) together
with the diverting gasket (3) off the
adapter plate (1). Make sure you do not
change the position of the diverting gas-
ket in the supply pressure regulator.
Î The long rubber finger of the diverting
gasket (3) must always point toward the
regulator outlet (reduced supply pres-
sure). See Fig. 10 and Fig. 11.
2. Insert the O-rings (2.1) into the bore-
holes of the intermediate plate (2).
Fig. 11: Mounting an intermediate plate onto Type 3372 Actuator
18
3. Place the intermediate plate onto the
connecting or adapter plate in such a
way that their three boreholes (arranged
in row) are located over the two 5 mm
boreholes of the adapter plate and the
boreholes (1.1) for the fastening screws
are aligned correctly.
4. Place the supply pressure regulator (4)
with the diverting gasket (3) onto the in-
termediate plate (2). Insert the longer
fastening screws and fasten the parts.
Supply air input
Output for reduced air
2
1.1
1
2
2.1
3
4
E
A
A
E
A
A
E
EB 8546 EN