Configuring Security and Other Services
Ethernet Port Redundancy
and the original active interface becomes the standby interface, while the original standby
interface becomes the active port.
NOTE
This feature is currently only available on ZoneDirector 3000/5000. ZoneDirector
1200 does not support port redundancy.
Port redundancy is disabled by default. If enabled, you can specify the time (in
milliseconds) after which the standby port will be enabled after a link recovery has been
detected, and after which the inactive port will be disabled after a link failure has been
detected.
To enable Ethernet Port Redundancy:
1. Go to Configure > Services.
2. Locate the Ethernet Port Redundancy section at the bottom of the page.
3. Enable the check box, and enter the Up Delay Time and Down Delay Time in the
text boxes.
• Up Delay Time: Specifies the time, in milliseconds, to wait before enabling a slave
after a link recovery has been detected. The default value is 50000, range is
0~1000000.
• Down Delay Time: Specifies the time, in milliseconds, to wait before disabling a
slave after a link failure has been detected. The default value is 0, range is
0~1000000.
4. Click Apply to save your changes.