6. Begin scrubbing floor by pushing machine forward and walking in straight line. Adjust solution flow
accordingly. Be sure to keep hands and feet clear of rotating brush/pad driver.
7. When finished scrubbing, turn both Brush Motor and Vacuum Motor switches to OFF position.
8. Use your foot to press the bottom of the Foot Pedal down until it clicks once, into a locked, raised
position, to raise the head.
9. Lift Squeegee Lift Lever to raise squeegee off floor and place lever in locked, raised position.
10. Check floor to ensure no puddles have been left by the squeegee or under the machine.
11. Move machine to safe and secure storage area.
12. Check battery charge level and charge batteries if necessary (see BATTERY MAINTENANCE and
BATTERY CHARGING on pgs 14-15).
13. If transporting the ProScrub off site, the Foot Pedal can be pushed further down to 2
"transport" position.
14. If transporting the ProScrub, squeegee can be removed without tools and placed in Control Panel
Cradle (see below and pg 8 for diagram).
PROSCRUB OPERATION HELPFUL HINTS
❖ The ProScrub works best when operating in a straight path; turning the machine at too sharp an
angle can result in squeegee spillover
❖ While scrubbing, periodically check the recovery tank. If foam buildup is heavy, use a defoamer
to prevent damage.
❖ If more scrubbing pressure is needed, pull brush lever upwards while operating machine.
❖ If squeegee is leaving streaks, lift squeegee to the "UP" position and wipe blades with clean, dry
cloth.
❖ Before stopping or turning, shut off solution flow to prevent excess solution on the scrub path.
❖ If you are stopping for more than five seconds, shut off brushes/pads to prevent floor damage.
❖ Frequently check battery meter for charge level. When it drops to the red zone, a recharge is
necessary. Do not continue to operate machine after the needle drops into the red zone. Battery
damage will occur.
HOW TO REMOVE THE PROSCRUB SQUEEGEE
1. Using the Squeegee Lift Lever, lower the squeegee to the floor (see pg 8 for diagram)
2. Unscrew the two squeegee attachment knobs
3. Disconnect the Vacuum Hose from the squeegee
4. Raise the Squeegee Lift Lever to the disengaged position, leaving the Squeegee Lever
disconnected on the floor
08-2017
PROSCRUB OWNER'S MANUAL PAGE 10
(WITHOUT TOOLS)
nd
locked,

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents