Programming Wireless Devices; Resetting Default Values; Reset The Master Code; Reset Programming Default Values - Bosch DS6R2 Installation And Operation Manual

Self-contained control panel
Table of Contents

Advertisement

DS6R2 | Installation and Operation Guide | 3.0 Programming
3.4

Programming Wireless Devices

The DS6R2 supports one RF3212 or RF3212E
Wireless Receiver. Mount the receiver up to 20 m
(65.7 ft) from the DS6R2.
The DS6R2 supports up to 6 key fobs and 18 wireless
devices, including motion detectors, smoke detectors,
and door contacts.
You can assign up to three wireless devices to a zone.
Refer to Table 5.
Table 5: Wireless Device Assignments
RF Zone
Program Address
37
1
38
39
40
2
41
42
43
3
44
45
46
4
47
48
49
5
50
51
52
6
53
54
N/A
55
N/A
56
N/A
57
N/A
58
N/A
59
N/A
60
Each wireless device is labeled with a unique, nine-
digit ID. Refer to Figure 11.
Figure 11: Device Identification Number
167770187
167770187
14
Wireless Device
Device 1
Device 2
Device 3
Device 1
Device 2
Device 3
Device 1
Device 2
Device 3
Device 1
Device 2
Device 3
Device 1
Device 2
Device 3
Device 1
Device 2
Device 3
Key fob 1
Key fob 2
Key fob 3
Key fob 4
Key fob 5
Key fob 6
16 7770187
or
16 7770 18 7
To add a wireless device to the system:
1. Enter Programming Mode.
2. Select the appropriate program address.
Refer to Table 5.
3. Enter the nine-digit ID for the wireless device.
4. For key fobs, set Program Address 35 to 1.
This setting enables up to six key fobs. Refer to
Table 3 on page 11.
You cannot assign the Master Code to a
key fob. Assign each key fob to a different
user. All Exit Delay and Entry Delay times
operate as if the DS6R2 was armed or
disarmed using a standard user code.
3.5

Resetting Default Values

3.5.1.

Reset the Master Code

1. Remove power from the DS6R2.
2. Place the J1 jumper across both pins (ON).
Refer to Figure 12.
Figure 12: J1 Jumper
DIP
4 5 6
TAMPER PROG
1- On
2- Off
3. Reapply power to the DS6R2.
4. Remove the J1 jumper (OFF).
3.5.2.

Reset Programming Default Values

1. Enter Programming Mode.
2. Enter [9][9][*] for Program Address 99.
3. Enter 18 for the programming value ([1][8]).
4. Press and hold [*] for 3 sec to exit from
Programming Mode.
The DS6R2 resets all programming values to the
original factory defaults.
Bosch Security Systems, Inc. | 4/08 | F01U081960-01