B. Clearances To Combustibles
Use the chart below together with the diagrams in Figure 4.3 to determine the required clearance for your particular installation.
Stove clearances are measured from the top plate to the combustible surface.
Chimney connector clearances are measured from the connector surface and take into account flue collar offset.
No Heat Shields
Top Exit, Rear Heat Shield
ONLY
Rear Exit, Rear Heat Shield
ONLY
Top Exit, Rear H.S., Single
Wall Connector Shields
1,2
Top Exit, Rear H.S., Double-
Wall Connector Shields
Chimney Connector
No Heat Shield
Using Heat Shields
2
Double-wall connector
3
Single Wall Connector
Double Wall Connector
Front Clearance to Combustibles
** A distance of 48" must be maintained between the stove and movable combustible items such as drying clothes, furniture, fire-
wood, etc.
When a rear heat shield is installed on a top exit stove, the shield insert must be attached to the shield so the area behind the flue
1
collar on the stove is protected.
Chimney connector heat shields must extend exactly 24" (610 mm) above the top of the stove. No shielding can be used on the
2
connector above 24" (610 mm). The unshielded chimney connector above the 24" (610 mm) point must be 13" (330 mm) from an
unprotected wall.
In top exit installations, this clearance requires the use of the rear stove heat shield with the flue collar cover plate installed.
3
Figure 4.2
9
Unprotected Surfaces
Stove Installed
Parallel to Wall
Side
(A) 24"
(610 mm)
(G) 24"
(610 mm)
(M) 24"
(610 mm)
(Q) 24"
(610 mm)
(Q) 24"
(610 mm)
1,3
Unprotected Surface / Vertical
15" (381 mm)
13" (330 mm)
Unprotected Surface / Horizontal
18" (457 mm)
Vermont Castings • Aspen 1920 Owner's Manual_R32 • 08/17
Stove Clearances
Stove in
Corner
Rear
Corners
(B) 13"
(C) 13"
(330 mm)
(330 mm)
(H) 11"
(I) 13"
(179 mm)
(330 mm)
(N) 11"
N/A
(179 mm)
(R) 9"
(S) 13"
(229 mm)
(330 mm)
(R) 7"
(S) 13"
(178 mm)
(330 mm)
6" (152 mm)
6" (152 mm)
Protected Surfaces
Stove Installed
Parallel to Wall
Side
Rear
(D) 16"
(E) 9"
(406 mm)
(229 mm)
(J) 16"
(K) 9"
(406 mm)
(229 mm)
(O) 16"
(P) 9"
(406 mm)
(229 mm)
(T) 16"
(U) 9"
(406 mm)
(229 mm)
(T) 16"
(U) 7"
(406 mm)
(178 mm)
Protected Surface / Vertical
11" (279 mm)
6" (152 mm)
6" (152 mm)
Protected Surface / Horizontal
11" (279 mm)
6" (152 mm)
All Installations: 48" (1219 mm)
Stove in
Corner
Corners
(F) 8"
(203 mm)
(L) 8"
(203 mm)
N/A
(V) 8"
(203 mm)
(V) 8"
(203 mm)
Save These Instructions