Airflow Direction

Airflow Direction

The airflow through the fan trays and power supplies on the Cisco NCS 5000 series router is either from the
port side exhaust or the port side intake, depending on how the modules were ordered. To ensure proper
airflow, you must make sure that when you install the switch its air intake is positioned in a cold aisle and the
air exhaust is positioned in a hot aisle for your data center.

Transceivers, Connectors, and Cables

Transceiver and Cable Specifications

To determine which transceivers and cables are supported by this router, see
support/interfaces-modules/transceiver-modules/products-device-support-tables-list.html.
To see the transceiver specifications and installation information, see
interfaces-modules/transceiver-modules/products-installation-guides-list.html.

RJ-45 Connectors

The RJ-45 connector connects Category 3, Category 5, Category 5e, Category 6, or Category 6A foil twisted-pair
or unshielded twisted-pair cable from the external network to the following module interface connectors:
• Router chassis
To comply with GR-1089 intrabuilding, lightning immunity requirements, you must use a foil twisted-pair
Caution
(FTP) cable that is properly grounded at both ends.
The following figure shows the RJ-45 connector.
Figure 34: RJ-45 Connector
1
Hardware Installation Guide for Cisco NCS 5500 Series Fixed-Port Routers
66
◦ CONSOLE port
◦ MGMT ETH port
Pin 1
http://www.cisco.com/c/en/us/
http://www.cisco.com/c/en/us/support/
2
Pin 2
System Specifications

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncs 5502Ncs 5501 seNcs 5502 seNcs 55a1-24hNcs 55a1-36h

Table of Contents