ResMed ClimateLineAir Oxy User Manual
Hide thumbs Also See for ClimateLineAir Oxy:

Advertisement

User guide
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ClimateLineAir Oxy and is the answer not in the manual?

Questions and answers

David Kaye
May 26, 2025

what does error 022 refer to and how do I correct it

Summary of Contents for ResMed ClimateLineAir Oxy

  • Page 1 User guide English...
  • Page 2: About Your Climatelineair

    The ClimateLineAir is heated air tubing that delivers the ™ desired temperature at your mask. ClimateLineAir Oxy is a variant of the ClimateLineAir that has a built-in oxygen connector to attach a supplemental oxygen supply. When used with the HumidAir humidifier, ClimateLineAir ™...
  • Page 3: Setup With Supplemental Oxygen

    4. Connect the assembled mask to the free end of the air tubing. Setup with supplemental oxygen To set up the ClimateLineAir Oxy with supplemental oxygen, perform the steps outlined in the setup section and the following additional steps. 1. Remove the cap from the oxygen connector.
  • Page 4: Climate Control

    These can be found at the end of your device User Guide. • If you use the ClimateLineAir Oxy without supplemental oxygen, make sure the cap of the oxygen connector is firmly attached.
  • Page 5: Climate Control Manual

    To adjust the Tube Temperature: 1. In My Options, turn the dial to highlight Tube Temp. and then press the dial. 2. Turn the dial to adjust the temperature and press the dial to save the change. Climate Control Manual Designed to offer you more flexibility and control over your settings, Climate Control Manual lets you adjust the temperature and humidity to the setting which is most...
  • Page 6: Caring For Your Climatelineair

    To adjust the Humidity Level: 1. In My Options, turn the dial to highlight Humidity Level and then press the dial. 2. Turn the dial to adjust the humidity level and press the dial to save the change. If you have been using Climate Control Manual and want to return to Climate Control Auto, follow the instructions below.
  • Page 7 Disconnecting 1. Hold the cuff of the air tubing, apply gentle pressure to the release buttons and pull it away from the device. 2. Hold both the cuff of the air tubing and the swivel of the mask, then gently pull apart. Note: Only hold and pull the cuff of the air tubing.
  • Page 8: Troubleshooting

    Troubleshooting If you have any problems, refer to the troubleshooting section of your device user guide or www.resmed.com. Technical specifications Environmental conditions Operating temperature: +41°F to +95°F (+5°C to +35°C) Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room.
  • Page 9: Limited Warranty

    If you need information on these disposal systems, please contact your local waste administration. The crossed-bin symbol invites you to use these disposal systems. If you require information on collection and disposal of your ResMed device please contact your ResMed office, local distributor or go to www.resmed.com/environment.
  • Page 10 See www.resmed.com for other ResMed locations worldwide. For patent and other intellectual property information, see www.resmed.com/ip. AirSense, AirCurve, ClimateLine, HumidAir and Lumis are trademarks of ResMed Ltd. ClimateLine is registered in U.S. Patent and Trademark Office. © 2017 ResMed Ltd. 378457/2 2017-10 ResMed.com...