TEST SETUP & TESTING for 380–430 MHz and 410–470 MHz

Test Check List

The following table summarises the required test setups.
No.
Test Name
1.
IFR System Setup
and Manual Test
Screen
2.
Base Station
Registration
3.
Receiver RSSI
4.
Transmitter Tests
Table 5.1-2
Test Setup
Terminal Setup
Control Channel
Traffic Channel
Time Slot
Country Code
Network Code
Base Color
Location Area
Min Rx Level
Max Tx Level
Access
Parameter
Mobile Power
35dBm (3.2W)
Burst Type
RF Gen Level
For 380–430MHz
terminal:
421.0125MHz
For 410–470MHz
terminal:
461.0125MHz
RF Gen Level
Cells Info
RSSI
TRACE
RF Gen Level
Range 1
Test Group 1
Burst Power
Timing Error
Frequency
Error
Vector Error
Test Setup
Test Conditions
For 380–430MHz
terminal: 840
For 410–470MHz
terminal: 2440
For 380–430MHz
terminal: 840
For 410–470MHz
terminal: 2440
3
262
75
1
224
-33dBm
Normal
-90dBm
-90dBm
-90dBm
5.1 - 3
Limits
-110dBm
35dBm (3.2W)
33–37dBm
<=0.25 Symbols
-/+ 100Hz
Max 10% RMS,
Max 30% Peak,
Max 5% Residual