LG GM360i Service Manual page 129

Hide thumbs Also See for GM360i:
Table of Contents

Advertisement

8. BGA Pin Map
Pin #
Description
1
DCS/PCS in
2
MODE SELECT

BAND SELECT (BS)
4
VBATT
5
VRAMP
6
TX_EN
7
GSM850 / 900 in
10
GSM850 / 900 out
12
DCS / PCS out
9, 1
Bypass Cap
8, 11, 14
GND
LG Electronics
LGE Internal Use Only
Function
DCS/PCS RF INPUT – DC blocked
MODE = High, the PAM operation in EDGE(SPSK) mode
MODE = Low, the PAM operation in GMSK mode.
BAND SELECT = Low, Low-band active
BAND SELECT = High, High-band active
Battery supply voltage, typ..0 – 4.5 V, nom. 1.6
DAC Control signal(analog), Nominal Vramp range is 0.2 to 1.6V
GMSK mode – Controls ramp profile and output power
EDGE mode – Controls ramp profile
TX_EN = High, PA is enabled for operation
TX_EN = Low, PA is sleep mode
GSM850 / GSM900 RF input –- DC blocked
GSM850 / GSM900 RF output –- DC blocked
DCS / PCS RF output –DC blocked
Connect 0.01uF bypass capacitor as close to pin as practical
Ground
U502(TQM7M5005H, SMPY0021101)
112/147
- 10 -
LGE Property
Copyright © 2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes