Deviation from Electrical- and Timing Specification:
The following table lists the deviations of the DC/AC characteristics from the specification in the
C167CR-4RM Data Sheet 7.97 and C167SR/CR-L25M Data Sheet Addendum 1998-03
Problem
Parameter
short name
DCVOL.1
Output low voltage
(Port0/1/4, ALE, RD#,
WR#, WRH#/BHE,
CLKOUT, RSTOUT#)
DCAH.1
ALE active current
DCRL.1
RD#/WR# active current
DCP6L.1
Port 6 active current
DCP0L.1
Port 0 configuration
current
DCHYS.1
Input Hysteresis
(Special Threshold)
Semiconductor Group
Symbol
V
OL
I
ALEH
I
RWL
I
P6L
I
P0L
HYS
Errata Sheet, C167CR-LM, ES-DB, DB, 1.1, Mh
Limit Values Unit Test
min.
max.
-
0.45
1000
-
instead of
500
-600
-
instead of
-500
-600
-
instead of
-500
-110
-
instead of
- 100
300
-
instead of
400
Condition
V
I
= 2.0 mA
OL
instead of
2.4 mA
µA
V
= 2.4 V
OUT
µA
V
= V
OUT
OLmax
µA
V
= V
OUT
OLmax
µA
V
= V
OUT
OLmax
mV
-
- 6 of 11 -

Advertisement

loading

This manual is also suitable for:

Sak-c167cr-l25m