Oam Errored-Frame-Period Threshold - HP A3100-8 v2 SI Command Reference Manual

A3100 v2 series
Hide thumbs Also See for A3100-8 v2 SI:
Table of Contents

Advertisement

undo oam errored-frame-period period
View
System view
Default level
2: System level
Parameters
period-value: Errored frame period event detection interval, ranging from 100 to 60000 (in
milliseconds).
Description
Use the oam errored-frame-period period command to set the errored frame period event detection
interval.
Use the undo oam errored-frame-period period command to restore the default.
By default, the errored frame period event detection interval is 1000 milliseconds.
For errored frame period event detection, the system first uses the following expression to convert the
errored frame period event detection interval to the maximum number of 64-byte frames that can be
transmitted through an Ethernet port in the period:
where bandwidth is the port bandwidth (in bps) and "period" is the configured period (in milliseconds).
Related commands: oam errored-frame-period threshold, display oam link-event, and display oam
configuration.
Examples
# Set the errored frame period event detection interval to 10 seconds (10000 milliseconds).
<Sysname> system-view
[Sysname] oam errored-frame-period period 10000

oam errored-frame-period threshold

Syntax
oam errored-frame-period threshold threshold-value
undo oam errored-frame-period threshold
View
System view
Default level
2: System level
Parameters
threshold-value: Errored frame period event triggering threshold, ranging from 0 to 4294967295.
Description
Use the oam errored-frame-period threshold command to set the errored frame period event triggering
threshold.
Use the undo oam errored-frame-period threshold command to restore the default.
bandwidth * period / (64 * 8 * 1000),
12

Advertisement

Table of Contents
loading