Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see the Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use the display oam configuration command to display global Ethernet OAM configuration, including
the periods and thresholds for Ethernet OAM link error event detection.
Related commands: oam errored-symbol period, oam errored-symbol threshold, oam errored-frame
period, oam errored-frame threshold, oam errored-frame-period period, oam errored-frame-period
threshold, oam errored-frame-seconds period, oam errored-frame-seconds threshold, oam timer hello,
and oam timer keepalive.
Examples
# Display global Ethernet OAM configuration.
<Sysname> display oam configuration
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds)
Errored-symbol Event threshold
Errored-frame Event period(in seconds)
Errored-frame Event threshold
Errored-frame-period Event period(in ms)
Errored-frame-period Event threshold
Errored-frame-seconds Event period(in seconds)
Errored-frame-seconds Event threshold
Configuration of the timer :
--------------------------------------------------------------------------
Hello timer(in ms)
Keepalive timer(in ms)
Table 3 Output description
Field
Configuration of the link event
window/threshold
Errored-symbol Event period (in
seconds)
Errored-symbol Event threshold
Errored-frame Event period (in
seconds)
Errored-frame Event threshold
Description
Detection intervals and triggering thresholds configured for link events
Errored symbol event detection interval, which defaults to one second.
Errored symbol event triggering threshold, which defaults to 1.
Errored frame event detection interval, which defaults to one second.
Errored frame event triggering threshold, which defaults to 1.
5
:
1
:
1
:
1
:
1
:
1000
:
1
:
60
:
1
:
1000
:
5000