MG6250 • Section Programming Guide

Wireless Module Options

Section
Option
1
Future use
2
Report Zone restore
Tamper recognition options (console tamper follows this option)
Disabled
Trouble only
3 & 4
Disarmed: Trouble only
Armed: Follow zone's alarm type
Disarmed: Audible alarm
Armed: Follow zone's alarm type
[2004]
5
Generate tamper trouble if detected on bypassed zone
Wireless transmitter supervision option
Disabled
Trouble only
6 & 7
Disarmed: Trouble only
Armed: Follow zone's alarm type
Disarmed: Audible alarm
Armed: Follow zone's alarm type
8
Generate supervision trouble if detected on bypassed zone
General Options
Section
Option
1
Restrict Arming when zone opens during exit delay
2
Acknowledge Trouble(s) before Arming
3
4
[2009]
5
6
GSM Antenna*
7
8
RF Frequency**
* If you are using a GPRS14 on an 868 MHz console, you cannot use GSM as a communication method when armed, unless an external antenna is connected.
Once the antenna is connected, you must set section [2009], option [7] to 'ON' , or 'external' .
** The frequency of the console cannot be changed, but must be programmed accordingly. Refer to the sticker on the console to view the set frequency, then
program it in option [8].
Version 1.6
Description
Description
Future Use
Future Use
Future Use
Future Use
OFF
-
 On bell cut-off
 On zone closure
3
OFF
OFF
ON
ON
 Disabled
6
OFF
OFF
ON
ON
 Disabled
OFF
 Disabled
 Disabled
-
-
-
-
Internal
868 MHz
Appendix A: EN 50131 Programming | 53
ON
-
4
OFF
ON
OFF
ON
 Enabled
7
OFF
ON
OFF
ON
 Enabled
ON
 Enabled
 Enabled
-
-
-
-
External
433 MHz