Section
Option
1
Volume boost on entry/exit
2
Volume boost in speaker phone mode
3
Check-in supervision time
4
RF jamming supervision
[2002]
5
Daylight savings time
6
Trouble latch
7
Need to code view troubles/events
8
Bell squawk when installer enters programming

Arming/Disarming Options

Section
Option
1
Bell squawk when arming/disarming with remote control
2
Stay arming switches to Force Stay arming
3
Sleep arming switches to Force Sleep arming
4
Full arming switches to Force Full arming
[2003]
5
Report system disarming
6
One-touch Stay arming
7
One-touch Sleep arming
8
One-touch Full arming

Wireless Module Options

Section
Option
1
Future use
2
Report Zone restore
Tamper recognition options (console tamper follows this option)
Disabled
Trouble only
3 & 4
Disarmed: Trouble only
Armed: Follow zone's alarm type
Disarmed: Audible alarm
Armed: Follow zone's alarm type
[2004]
5
Generate tamper trouble if detected on bypassed zone
Wireless transmitter supervision option
Disabled
Trouble only
6 & 7
Disarmed: Trouble only
Armed: Follow zone's alarm type
Disarmed: Audible alarm
Armed: Follow zone's alarm type
8
Generate supervision trouble if detected on bypassed zone
Section
Option
1
Input/Output 1 used as
2
Input/Output 2 used as
3
PGM 1 normal state
4
PGM 2 normal state
[2005]
5
Future use
6
Live display mode for wireless keypad
7
End-of-Line (EOL) resistor
8
Future use
30 | System Programming
Description
Description
Description
Description
MG6250 • Section Programming Guide
OFF
 Disabled
 Disabled
 24 Hrs.
 Disabled
 Disabled
 Disabled
 Disabled
 Disabled
OFF
 Disabled
 Disabled
 Disabled
 Disabled
 Always
 Disabled
 Disabled
 Disabled
OFF
-
 On bell cut-off
3
OFF
OFF
ON
ON
 Disabled
6
OFF
OFF
ON
ON
 Disabled
OFF
 PGM 1
 PGM 2
 N. O.
 N. O.
-
 Disabled
 No EOL
-
ON
 Enabled
 Enabled
 80 minutes
 Enable
 Enable
 Enable
 Enable
 Enable
ON
 Enabled
 Enabled
 Enabled
 Enabled
After alarm
only
 Enabled
 Enabled
 Enabled
ON
-
 On zone closure
4
OFF
ON
OFF
ON
 Enabled
7
OFF
ON
OFF
ON
 Enabled
ON
 Zone 1
 Zone 2
 N. C.
 N. C.
-
 Enabled
 Use EOL resistor
-